4. Periodic Test by Installer Code
D-306488 WK250 Installer’s Guide
79
Option
Instructions
TEST ONE DEVICE
Select a specific device group you wish to test. For example, Motion Sensors.
Press
to enter the "
TEST ONE DEVICE
" sub menu and use
to scroll
through the device families. Press
to enter the < device family > sub menu. For
example: "
MOTION SENSORS
".
The following screens will appear: "
Xxx:<device name>
"
<location>
Where "
Xxx
" indicates the device number.
If there is no device, the following screen will appear: "
NO EXISTING DEV.
".
Press
to test the selected device. The following screen will appear:
"
Z01 ACTIVATE NOW
".
Walk throughout the site to test the detectors / sensors or press any key of the selected
handheld device to initiate the test.
During testing, you can also check the signal strength indication of each device, (for
further details, refer to the device Installation Instructions).
At the end of the test process the panel will revert to the last selected device group.
To test the microwave range of the dual detector:
1.
Press
to enter the "
TEST ONE DEVICE
" sub menu and use
to
navigate to "
MOTION SENSORS
".
2.
Press
; the following screens will appear: "
Z01:Motion Sens
"
<location>
.
3.
Press
continuously to select a different zone number.
4.
Press
; If the selected device is Tower-32AM PG2, the following screens will
appear: "
<OK MW ADJUST>
"
"<NEXT> TEST ONE"
.
To test the microwave range, go to step 5. To test a different microwave range, go to
step 7.
5.
Press
; the following screen will appear: "
ACTIVATE MW NOW
".
6.
Activate the device; the screen will return to "
TEST ONE DEVICE
".
You can now repeat the procedure for another dual detector.
7.
Press
to select the sensitivity setting.
8.
Press
continuously to select between "
Minimum
" (default), "
Medium
" or
"
Maximum
"
9a
. Press
; the panel will receive an acknowledgement from the device that is
indicated by a black box next to the selected setting. Thereafter, the screen
momentarily changes to "
ACTIVATE MW NOW
" and then returns to the selected
setting.
9b
. If you press
, the adjustment procedure ends.
Important
: The procedure mentioned above is for testing purposes only and does not
change the detector settings. The settings must be saved through the
MODIFY DEVICES menu.
To test the shock detector:
CONTACT SENSORS
MOTION SENSORS
GLASSBREAK SENS.
SHOCK SENSORS