3. Programming
D-306488 WK250 Installer’s Guide
45
Option and default
Configuration Instructions
RCVR1 or RCV1) and a 2
nd
Account (subscriber) number (12:RCVR 2 ACCOUNT)
that will identify the system to the 2
nd
Monitoring Station (designated as RCVR2 or
RCV2). Each of the Account numbers consists of 6 hexadecimal digits.
12:RCVR2 ACCOUNT
005678
Master Installer only
To enter Hexadecimal digits, use the following table:
Entering Hexadecimal Digits
Digit
0…..9
A
B
C
Keying
0…..9
[#]
[0]
[#]
[1]
[#]
[2]
Digit
D
E
F
Keying
[#]
[3]
[#]
[4]
[#]
[5]
16:PSTN/GSM RCV1
The WP can be programmed to report the event messages defined in the Report
Events option (option 01) to two Alarm Format Receivers via PSTN telephone line
and/or GSM analog voice channel (if equipped with GSM module), using standard
PSTN alarm formats (i.e. SIA, Contact-ID and Scancom). The reporting format is
defined in the "PSTN Report Format" option (option 41).
Enter the two respective telephone numbers (
including area code
– maximum 16
digits) of the Alarm Format Receiver 1 located at the 1
st
Monitoring Station (16:
PSTN/GSM RCV1) and alarm format Receiver 2 located at the 2
nd
Monitoring Station
(17: PSTN/GSM RCV2).
17:PSTN/GSM RCV2
Master Installer only
Note:
If any of the phone numbers programmed herein contain an
area code
identical to
the area code of the PSTN telephone line to which the system is connected, you should
refer to the "
AREA CODE
" option in section 3.6.2.and act as instructed there.
Digit Keying Digit Significance
A
[#]
[0] The dialer waits 10 seconds or waits for a dial tone, whichever
comes first and then dials. Applicable only at the 1
st
digit.
D
[#]
[3] The dialer waits 5 seconds for a dial tone and goes on hook if none
is received. Applicable only at the 1
st
digit.
E
[#]
[4] The dialer waits 5 seconds. Applicable only in the middle of the
number.
To
move the cursor
and
clear digits
, use the
"String Editor's"
keys as described
in the table in section 3.8.1.
21:IP RCVR 1
000.000.000.000
If equipped with GSM or Broadband/PowerLink modules, the WP can be programmed
to report event messages defined in the Report Events option (option 01) to two IP
Receivers if applicable on the Monitoring Station. IP reporting can be performed using
the GPRS (IP) channel that uses SIA IP format. Alternatively, you can use the
Broadband IP channel that uses SIA IP or PowerNet format.
Enter the two IP addresses (000.000.000.000) of the IP Receiver 1 located at the 1
st
Monitoring Station (21: IP RCVR 1) and IP Receiver 2 located at the 2
nd
Monitoring
Station (22: IP RCVR 2).
22:IP RCVR 2
000.000.000.000
Master Installer only
26:SMS RCVR
If equipped with GSM module, the WP can be programmed to report the event
messages defined in Report Events option (option 01) to two SMS Receivers via the
GSM SMS channel using a special SMS text format. For further details concerning the