3. Programming
34
D-306488 WK250 Installer’s Guide
3.5.6 Configuring Audible & Visual User Interface
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 3.5.1.
Option and default
Configuration Instructions
51:PIEZO BEEPS
on
Define whether the panel will sound the exit/entry warning beeps during exit and
entry delays or not. An additional option is to mute the warning beeps only when the
system is armed “HOME”.
When Partitioning is
disabled
Options:
ON
,
OFF when home
(default in USA) and
off
,
and
OFF exit home
.
The volume level of the exit / entry beeps can be modified by pressing the
button
on the keypad to increase the volume, or by pressing the
button to decrease the
volume.
51:PIEZO BEEPS
Def:P1 P2
P3
Define whether the panel will sound the exit/entry warning beeps during exit and entry
delays or not. An additional option is to mute the warning beeps only when the system
is armed “HOME”.
The pushbuttons
,
,and
provide selection of the corresponding
partitions. Pressing each button repeatedly will toggle between each option.
When Partitioning is
enabled
Options: (enable beeps),
H
(OFF when home),
h
(OFF exit home) and
disable
beeps.
The volume level of the exit / entry beeps can be modified by pressing the
button
on the keypad to increase the volume, or by pressing the
button to decrease the
volume.
52:TROUBLE BEEPS
off at night
Under trouble conditions, the control panel sounder emits a series of 3 short
reminder beeps once per minute. Define whether to enable or disable this reminder
beeping or just disable it at night. The “night” hours are defined in the factory but
are usually from 8 PM (20:00) until 7:00 AM.
Options:
ON
(default in USA);
OFF at night
and
OFF
.
53:MEMORY PROMPT
on
Define whether or not the user will receive "Memory" indication that an alarm has
been activated.
Options:
on
and
off
.
54:LOW-BAT ACK
off
You can activate or deactivate the "Low Battery Acknowledge" requirement from
the user whose keyfob's battery is low.
Options:
off
– acknowledge not needed;
on
– acknowledge required.