3. Programming
32
D-306488 WK250 Installer’s Guide
Option and default
Configuration Instructions
Options:
after 5 minute, after 30 minute
,
after 60 minute
or
after 3 hours.
Note:
To comply with
EN
requirements, the time delay must not exceed 60 min.
36:CONFIRM ALARM
in 60 minutes
Define a specific time period that if 2 successive alarms occur, the second alarm will be
considered as a
confirmed alarm
, (see section 3.6.4 option 61).
Options:
in 30
/
45
/
60
/
90 minutes
Note:
In some WP variants, this menu is displayed in the Operation Mode only.
37:ABORT TIME
in 30 seconds
The WK250 can be configured to provide a delay before reporting an alarm to the
monitoring station (not applicable to alarms from 24H SILENT and EMERGENCY
zones). During this delay period, the siren sounds but the alarm is not reported. If the
user disarms the system within the delay time, the alarm is aborted. You can activate the
feature and select the "Abort Time" interval.
Options:
in 00
(default in USA)/
15
/
30/45/60 seconds
;
in 2/3/4 minutes
Notes:
1. In some WP variants, this menu is displayed in the Operation Mode only.
2. To comply with
UL
or
CP-01
requirements, the abort time must not exceed 45 sec.
38:CANCEL ALARM
in 5 minutes
The WK250 can be configured to provide a ”Cancel Alarm” time window that starts upon
reporting an alarm to the Monitoring Station. If the user disarms the system within that
"cancel alarm" time, a “cancel alarm” message is sent to the Monitoring Station indicating
that the alarm was canceled by the user.
Previously known as
"ALARM CANCEL"
Options:
not active
(default in USA);
in 1
/
5
/
15
/
60 minute(s)
and
in 4
hours
.
Notes:
1. In some WP variants, this menu is displayed in the Operation Mode only.
2. Since the Soak Test zone does not report an alarm event to the Monitoring Station, the
WP will not send a “cancel alarm” message to the Monitoring Station even if disarmed
within the Cancel Alarm period.
3. To comply with
CP-01
requirements, "1 minute" option must not be used.
39:ALARM RESET
by user
The WK250 provides you with the following configurable options for resetting the alarm
condition and rearming the system:
By the user as usual
by user
. By the engineer (installer) by entering and exiting the
"Installer Mode" or by accessing the system remotely via the telephone using the Installer
Code (
by engineer
). For accessing the system via the telephone, refer to the
WP8010/WP8030 User Guide, Chapter 7 – "Remote Control by Telephone" and use the
installer code instead of the user code.
Previously known as
"RESET OPTIONS"
Note:
This feature is not applicable in the USA.
40:ABORT FIRE T.
in 00 seconds
Select the length of time allowed by the system to abort a Fire alarm. The alarm system is
programmed to provide an “abort interval” that starts upon detection of a Fire event.
During this interval, the buzzer sounds a warning but the siren remains inactive and the
alarm is not reported. If the user disarms the system within the allowed abort interval, the
alarm is aborted.