3. Programming
D-306488 WK250 Installer’s Guide
75
Option and default
Configuration Instructions
09:ENTRY DELAY 2
30 seconds
Slow-rate warning beeps start sounding once the door is opened, until the last 10
seconds of the delay, during which the beeping rate increases. Locations No. 1 (entry
delay 1) and 2 (entry delay 2) allow you to program the length of these delays.
Options:
30/45/60 seconds
;
3/4 minutes
10:ABORT TIME
in 15 seconds
The WP can be configured to provide a delay before reporting an alarm to the
monitoring station (not applicable to alarms from FIRE, 24H SILENT, EMERGENCY,
GAS FLOOD and TEMPERATURE zones). During this delay period, the external siren
will not sound and the alarm is not reported. If the user disarms the system within the
delay time, the alarm is aborted.
Options:
in 15/30/45 seconds
11:CANCEL ALARM
in 5 minutes
Define the ”cancel alarm” period that starts upon reporting an alarm to the Monitoring
Station. If the user disarms the system within that time period, a “cancel alarm”
message is sent to the Monitoring Station.
Options:
in 5/15/60 minutes
;
in 4 hours
12:CNCEL ANOUNCE
enable
Define whether a special beep will sound when an alarm cancel event is sent to the
monitoring station.
Options:
enable
and
disable
13:ABORT ANOUNCE
enable
Define that when the user disarms the system within the allowed abort interval a special
beep will sound to indicate "no alarm transmission".
Options: :
enable
and
disable
3.14.6 DEFAULT Setup
13:OPERATION MOD
⋅⋅⋅
05:OTHERS SETUP
Enter the "
05:OTHERS SETUP
" menu, and press
to configure its settings.
Option and default
Configuration Instructions
01:DISARM OPTION
anytime
Certain regulations require that when the system is armed in AWAY mode, it may
not be disarmed from the outside of the house (such as by keyfobs) before entering
the protected premises and activating an "Entry Delay" zone. To answer this
requirement, the WP provides you with the following configurable options to disarm
the system:
A:
At "
any time
" (default), the system can be disarmed at all times from all devices.
B:
During entry delay, the system can be disarmed only using keyfob or prox
operated devices ("
on entry wrless
"
)
.
C:
During entry delay by code, the system can be disarmed only using WP panel
keypad ("
entry + away kp.
").
D:
During entry delay, the system can be disarmed using keyfobs or by code using
the WP panel keypad ("
on entry all.
").