3. Programming
D-306488 WK250 Installer’s Guide
55
PGM: BY SENSOR
Activates the PGM output upon activation of any one of up to 3 sensors (zones) in
the systems irrespective of whether the system is armed or disarmed.
To configure:
Press
to enter the "
PGM: BY SENSOR
" sub menu and then select the Zone
you wish to program, for example
"Zone A
". If the zone was configured before, the
display shows the current zone number "
(Z:xx)
" and if not, the zone number will be
blank ("
Z:_ _
"). To configure the zone number, press
. Enter the two digits of
the Zone number (between 01 - 64) to activate the PGM output and press
to
confirm. To add another sensor, select any of the other two options ("
Zone B
" and
"
Zone C
") and repeat the above process.
When done press
to return.
Zone A Z:_ _
Zone B Z:_ _
Zone C Z:_ _
disable
Options:
disable
;
turn ON
;
turn OFF
;
activate PULSE
;
toggle
Note:
If you select
toggle
, the PGM output will be turned on upon event occurrence in
any of these zones and will be turned off upon next event occurrence, alternately
.
PGM: BY LINE FAIL
by line fail NO
Activates the PGM output following failure of the PSTN line
Options:
by line fail NO; by line fail YES.
PGM: BY SIREN
disable
Determine to activate the PGM output as an external wired siren.
Options:
disable
;
ON&OFF by siren
.
PGM:PULSE TIME
pulse time 2s
Determine the PGM output pulse time. This value is the same for all events (by ARM
AWAY, by ARM HOME, by DISARM etc.) which were selected with "activate PULSE"
option.
Options:
pulse time 2s
;
pulse time 30s
;
pulse time 2m
;
pulse time 4m
.