3. Programming
D-306488 WK250 Installer’s Guide
19
Zone No. and Type
Description
Zxx: ZONE TYPE
7.Perim-Follow
Similar to "Perimeter" zone, but is temporarily ignored by the alarm system during
entry/exit delay periods. Usually used for sensors protecting the route between the
entrance door and the control panel.
Zxx: ZONE TYPE
8.24h silent
This zone type is active 24 hours, even when system is DISARMED. It is used to
report alarm events from sensors or manually activated buttons to the monitoring
station or private telephones (as programmed) without activating the sirens.
Zxx: ZONE TYPE
9.24h audible
Similar to 24hr silent zone, but also provides an audible siren alarm.
Zxx: ZONE TYPE
10. Emergency
This zone type is active 24 hours, even when the system is DISARMED. It is used
to report an emergency event and to initiate an
Emergency call
to the monitoring
stations or private telephones (as programmed).
Zxx: ZONE TYPE
11. Arming Key
An Arming key zone is used to control the arming and disarming of the system.
This is achieved by an external wired system or a simple key switch connected to
the panel's wired zone input or the wired input of a device.
Note:
If the wired input of the panel or device is closed, the control panel will be
armed. If it is opened, the control panel will be disarmed - refer to the
WP8010/WP8030 Installer’s Guide, Figure 3.6b (WP8010) / Figure 4.9b (WP8030),
or, WP8033 Installer’s Guide, Figure 3.8b.
Zxx: ZONE TYPE
12. Non-Alarm
This zone does not create an alarm and is often used for non-alarm applications.
For example, a detector used only for sounding a chime.
Zxx: ZONE TYPE
13.Fire
A Fire zone is used for connecting the MC-302E (magnetic contact with hard-wired
input) to a wired smoke detector.
Zxx: ZONE TYPE
17.Guard keybox
A Guard keybox zone is usually connected to a metal safe containing the physical
keys needed to enter the building. Following an alarm, the safe becomes available
to a trusted Guard who can open the Guard keybox, obtain the keys and enter the
secured premises. The Guard keybox zone acts just like a 24H audible zone. The
Guard keybox zone also provides automatic audible internal sounder and external
siren alarm that is immediately reported to the Monitoring Station (and does not
depend on the Abort Time).
Note:
Opening/closing the Guard keybox causes the WP to signal the Monitoring
Station.
Zxx: ZONE TYPE
18. Outdoor
A zone for outdoor areas where an activated alarm does not indicate intrusion into
the house. This zone type generates an alarm when the system is armed both in
AWAY and HOME modes. Events are sent to private phones and not to the
Monitoring Station.
Note:
The PIR camera / Outdoor PIR camera detector cannot be set to Outdoor
Zone Type.
(*)
These Zone types are useful mainly when arming and disarming the system from inside the protected
premises. If you arm and disarm the system from outside (without tripping any sensor), such as using a
keyfob, it is preferred to use the other Zone Types.