3. Programming
46
D-306488 WK250 Installer’s Guide
Option and default
Configuration Instructions
27:SMS RCVR2
SMS text format please contact DSC.
Enter the two telephone numbers (including area code – maximum 16 digits).of the
SMS Receiver 1 located at the 1
st
Monitoring Station (26:SMS RCVR 1) and SMS
Receiver 2 located at the 2
nd
Monitoring Station (27:SMS RCVR 2).
Master Installer only
Note:
To enter the international prefix (
) at the 1
st
digit – key-in [#]
[1].
41:PSTN FORMAT
SIA
The WP can be programmed to report the event messages defined in Report Events
option (option 01) to two Alarm Format Receivers (see options 16 & 17) via PSTN
telephone line and/or GSM analog voice channel (if equipped with GSM module)
using standard PSTN alarm formats (i.e. SIA, 4/2 1900/1400; 4/2 1800/2300,
Contact-
ID and Scancom).
Select which of the reporting formats the system will use to report the events to the
two Alarm Format Receivers
PSTN/GSM RCVR 1
and
PSTN/GSM RCVR 2.
Make sure that the receivers used by the Monitoring Stations are of the compatible
models listed below and that the receiver used can receive the format you select.
Compatible Alarm Format Receivers:
Osborne-Hoffman model 2000; Ademco Model 685; FBII Model CP220; Radionics
Model D6500; Sur-Gard Model SG-MLR2-DG and Silent Knight Model 9500.
Master Installer only
Options:
SIA
;
4/2 1900/1400
;
4/2 1800/2300
;
Scancom
;
SIA text
and
Contact ID
.
46:PSTN RETRIES
4 attempts
Define the number of times the system will retry to report to the Monitoring Station in
case of failure to report via the PSTN telephone line connection.
Options:
2 attempts
;
4 attempts
;
8 attempts
;
12 attempts
and
16 attempts
.
47:GSM RETRIES
4 attempts
Define the number of times the system will retry to report to the Monitoring Station in
case of failure to report via the cellular connection - GPRS (IP), GSM and SMS.
Options:
2 attempts
;
4 attempts
;
8 attempts
;
12 attempts
and
16 attempts
.
48:BB IP RETRIES
4 attempts
Define the number of times the system will retry to report to the Monitoring Station in
case of failure to report via the Broadband Module connection.
Options:
2 attempts
;
4 attempts
;
8 attempts
;
12 attempts
and
16 attempts
.
51:TEL AUTO TEST
Test OFF
To verify a proper communication channel, the WP can be configured to send a test
event to the Monitoring Station via PSTN periodically. You can set the interval
between the consecutive test events or disable the automatic sending of this event
entirely. If the interval is set for every one day or more then the exact hour of reporting
can be selected with option 52.
Options:
test OFF
;
every 1
/
2
/
5
/
7
/
14
/
30 day(s)
; and
every 5 hours
.
52:AUTO TST TIME
12:00
Enter the exact time (
auto test time
) during the day at which the Auto Test message
(if enabled in option 51) will be sent to the Monitoring Station.
Note:
If the AM/PM format is used, you can set the "AM" and the "PM" digits with the
keypad’s numbered
buttons
.