5.0 Operation
- 43 -
5.1 Basic Operation
5.1.1 Connectivity
Each SG-CPM5 has one static IP address and a number of associated ports. The configuration management, done from the SG-Systems Console Soft-
ware, is located on port 1024. The SG-Systems Console Software is provided for Microsoft Windows operating system (refer to the console doc-
umentation for compatibility listing), which provides a graphical style menu for configuration. Additional features are available with the SG-Systems
Console software including storage of virtual receiver setups and configuration wizards.
5.1.2 SG-Systems Console Software
The Console software is intended to be the primary method of programming the system. Refer to the SG-Systems Console Manual for details.
5.1.2.1 Visual Verification
This port is used by the SG-Systems Console to accept Visual verification Files such as Images, Sound, and Movie files.
5.1.2.1.1 Connectivity
The Visual verification port is TCP/IP port 2025 on the SG-CPM5 that the Console connects to.
5.1.2.1.2 Functionality
All the commands are XML files that are transmitted over the TCP/IP stream. The XML files parse all the information generated by the receiver for
each visual verification event.
5.1.2.1.3 Header File
Included in each folder is an XML file that contains account and alarm specific information. This file can be viewed with any text editor.
5.1.2.1.4 Unique ID
The Unique ID is a number that is unique to each film, making it easier to look up.
The Unique ID is a 20-digit number in which the first ten digits are the 10-digit transmitter account number.
5.1.2.1.5 Automation and Printer messages
When a Visual verification event is received, the SG-System 5 will output a message to automation and printer.
Automation message: 001001[#XXXXXXXXXX|Idu255]
Printer message: SG -01-001-XXXX-Idu255 -IMAGE VERIFICATION INITIATED
5.1.2.1.6 ACK
Once a command is issued by either the SG-System 5 or the Console Software/Automation Software it should return an ACK within 4 seconds.
5.1.2.1.7 NACK from the Console or Automation Software
If the receiver sends any command and receives a NACK response from the Console software the receiver will re-send this command up to 4 times.
After the fourth NACK to the same message, the system shall generate an internal communication error and output the applicable information for the
event to the printer. The system will not change the automation slot that it is currently in as the response to the message is a valid command (NACK). If
at any time in the sequence the system receives an ACK to the message the system shall accept this and clear any counters for the previous failed
attempts.
The automation/printer message will be outputted via the SG-automation/printer path indicating that a message has failed:
Visual verification output
Communication Failure
001000[#0000|NYOssSS]
SG -01-000-0000-NYOssSS-Visual: Inter-Comm Error: DDDDD AAAAAAAAAA – Unique ID
After the 4th re-try, the Line card will move onto the next command that it has to send.
S
G
-S
ys
te
m
5
O
pe
ra
ti
ng
M
anua
l
Содержание SG-System 5
Страница 68: ...6 0 Options 68 Automation Mode Diagrams FIGURE 6 1 Flow Diagram for Loop Mode 0 SG System 5 Operating Manual ...
Страница 69: ...6 0 Options 69 FIGURE 6 2 Flow Diagram for Fallback Mode 1 SG System 5 Operating Manual ...
Страница 70: ...6 0 Options 70 FIGURE 6 3 Flow Diagram for All Mode 2 SG System 5 Operating Manual ...
Страница 71: ...6 0 Options 71 FIGURE 6 4 Flow Diagram for IP Fallback Mode 3 SG System 5 Operating Manual ...