Appendix D: Events & Messages
- 92 -
Appendix D: Events & Messages
SG-CPM5 Messages
NOTE: The slots (ss) of the SG-CPM5 are C1 for the primary SG-CPM5 and C2 for secondary SG-CPM5.
Description/Event
Automation message
Printer Message
SG-PSU5 1 Failure -PSU is Missing, or any other
PSU failure
001000[#0000|NAT0000]
SG -01-000-0000-NAT0000-SG-PSU 1 Failed
SG-PSU5 1 Restoral
001000[#0000|NAR0000]
SG -01-000-0000-NAR0000- SG-PSU 1 Restored
SG-PSU5 2 Failure -PSU is Missing, or any other
PSU failure
001000[#0000|NAT0001]
SG -01-000-0000-NAT0001- SG-PSU 2 Failed
SG-PSU5 2 Restoral
001000[#0000|NAR0001]
SG -01-000-0000-NAR0001- SG-PSU 2 Restored
SG-PSU5 Compatibility Failure (the two installed
power supplies are not at the same power rating)
001000[#0000|NYP00FF]
SG -01-000-0000-NYP00FF-PSU Compatibility Failed
SG-PSU5 Compatibility Restore
001000[#0000|NYQ00FF]
SG -01-000-0000-NYQ00FF-PSU Compatibility Restore
Fan Circuit 1 Failure (LINE CARD FAN 1)
001000[#0000|NYX0100]
SG -01-000-0000-NYX0100-Fan Circuit 1 Failed
Fan Circuit 1 Restoral Fan (LINE CARD FAN 1)
001000[#0000|NYZ0100]
SG -01-000-0000-NYZ0100-Fan Circuit 1 Restored
Fan Circuit 2 Failure Fan (LINE CARD FAN 2)
001000[#0000|NYX0200]
SG -01-000-0000-NYX0200-Fan Circuit 2 Failed
Fan Circuit 2 Restoral Fan(LINE CARD FAN 2)
001000[#0000|NYZ0200]
SG -01-000-0000-NYZ0200-Fan Circuit 2 Restored
Fan Circuit 3 Failure (LINE CARD FAN 3)
001000[#0000|NYX0300]
SG -01-000-0000-NYX0300-Fan Circuit 3 Failed
Fan Circuit 3 Restoral Fan(LINE CARD FAN 3)
001000[#0000|NYZ0300]
SG -01-000-0000-NYZ0300-Fan Circuit 3 Restored
Fan Circuit 4 Failure Fan(LINE CARD FAN 4)
001000[#0000|NYX0400]
SG -01-000-0000-NYX0400-Fan Circuit 4 Failed
Fan Circuit 4 Restoral Fan(LINE CARD FAN 4)
001000[#0000|NYZ0400]
SG -01-000-0000-NYZ0400-Fan Circuit 4 Restored
Fan Circuit 5 Failure (SG-CPM5 FAN 1)
001000[#0000|NYX0500]
SG -01-000-0000-NYX0500-Fan Circuit 5 Failed
Fan Circuit 5 Restoral Fan (SG-CPM5 1 FAN)
001000[#0000|NYZ0500]
SG -01-000-0000-NYZ0500-Fan Circuit 5 Restored
Fan Circuit 6 Failure Fan (SG-CPM5 2 FAN)
001000[#0000|NYX0600]
SG -01-000-0000-NYX0600-Fan Circuit 6 Failed
Fan Circuit 6 Restoral Fan (SG-CPM5 2 FAN)
001000[#0000|NYZ0600]
SG -01-000-0000-NYZ0600-Fan Circuit 6 Restored
TCP/IP SG-CPM5 1 Printer Failure
001000[#0000|NVZ0100]
SG -01-000-0000-NVZ0100-TCP/IP 1 Printer Failed
TCP/IP SG-CPM5 1 Printer Restoral
001000[#0000|NVY0100]
SG -01-000-0000-NVY0100-TCP/IP 1 Printer Restored
TCP/IP SG-CPM5 2 Printer Failure
001000[#0000|NVZ0200]
SG -01-000-0000-NVZ0200-TCP/IP 2 Printer Failed
TCP/IP SG-CPM5 2 Printer Restoral
001000[#0000|NVY0200]
SG -01-000-0000-NVY0200-TCP/IP 2 Printer Restored
Serial SG-CPM5 1 Printer 1 Failure
001000[#0000|NVZ0102]
SG -01-000-0000-NVZ0102-Serial 1 printer Failed
Serial SG-CPM5 1 Printer 1 Restoral
001000[#0000|NVY0102]
SG -01-000-0000-NVY0102-Serial 1 printer Restored
Serial SG-CPM5 2 Printer 1 Failure
001000[#0000|NVZ0202]
SG -01-000-0000-NVZ0202-Serial 2 printer Failed
Serial SG-CPM5 2 Printer 1 Restoral
001000[#0000|NVY0202]
SG -01-000-0000-NVY0202-Serial 2 printer Restored
Serial SG-CPM5 1 Printer 2 Failure
001000[#0000|NVZ0103]
SG -01-000-0000-NVZ0103-Serial 3 printer Failed
Serial SG-CPM5 1 Printer 2 Restoral
001000[#0000|NVY0103]
SG -01-000-0000-NVY0103-Serial 3 printer Restored
Serial SG-CPM5 2 Printer 2 Failure
001000[#0000|NVZ0203]
SG -01-000-0000-NVZ0203-Serial 4 printer Failed
Serial SG-CPM5 2 Printer 2 Restoral
001000[#0000|NVY0203]
SG -01-000-0000-NVY0203-Serial 4 printer Restored
SG-TCP/IP SG-CPM5 1 Failure
001000[#0000|NNT0100]
SG -01-000-0000-NNT0100-SG-TCP/IP 1 Failed
SG-TCP/IP SG-CPM5 1 Restoral
001000[#0000|NNR0100]
SG -01-000-0000-NNR0100-SG-TCP/IP 1 Restored
SG-TCP/IP SG-CPM5 2 Failure
001000[#0000|NNT0200]
SG -01-000-0000-NNT0200-SG-TCP/IP 2 Failed
SG-TCP/IP SG-CPM5 2 Restoral
001000[#0000|NNR0200]
SG -01-000-0000-NNR0200-SG-TCP/IP 2 Restored
SG-TCP/IP SG-CPM5 1 Visual automation Failure
001000[#0000|NNT0150]
SG -01-000-0000-NNT0150-SG-Visual Verification 1 Failed
SG-TCP/IP SG-CPM5 1 Visual automation Restoral 001000[#0000|NNR0150]
SG -01-000-0000-NNR0150-SG- Visual Verification 1 Restored
SG-TCP/IP SG-CPM5 2 Visual automation Failure
001000[#0000|NNT0250]
SG -01-000-0000-NNT0250-SG- Visual Verification 2 Failed
SG-TCP/IP SG-CPM5 2 Visual automation Restoral 001000[#0000|NNR0250]
SG -01-000-0000-NNR0250-SG- Visual Verification 2 Restored
SG-Serial 1 SG-CPM5 1 Failure
001000[#0000|NYC0101]
SG -01-000-0000-NYC0101-SG-SERIAL 1 Failed
SG-Serial 1 SG-CPM5 1 Restoral
001000[#0000|NYK0101]
SG -01-000-0000-NYK0101-SG-SERIAL 1 Restored
SG-Serial 1 SG-CPM5 2 Failure
001000[#0000|NYC0201]
SG -01-000-0000-NYC0201-SG-SERIAL 2 Failed
SG-Serial 1 SG-CPM5 2 Restoral
001000[#0000|NYK0201]
SG -01-000-0000-NYK0201-SG-SERIAL 2 Restored
S
G
-S
ys
te
m
5
O
pe
ra
ti
ng
M
anua
l
Содержание SG-System 5
Страница 68: ...6 0 Options 68 Automation Mode Diagrams FIGURE 6 1 Flow Diagram for Loop Mode 0 SG System 5 Operating Manual ...
Страница 69: ...6 0 Options 69 FIGURE 6 2 Flow Diagram for Fallback Mode 1 SG System 5 Operating Manual ...
Страница 70: ...6 0 Options 70 FIGURE 6 3 Flow Diagram for All Mode 2 SG System 5 Operating Manual ...
Страница 71: ...6 0 Options 71 FIGURE 6 4 Flow Diagram for IP Fallback Mode 3 SG System 5 Operating Manual ...