2.0 Introduction
- 10 -
l
Provides higher line security than conventional dial up panels with the polling feature
l
Quicker transmission since dialing or handshaking is not required
l
Network trouble detection is displayed on LCD/printer and automation software
l
Data network polling environment for replacement of an existing DVACS network using a TL-300. Meets the 90-second ULC requirement for
this option
l
SIA event descriptors are used when transmitting information to the central station from the control panel through the PCLink connection
l
A security function communicates to the central station when a module is removed and replaced
l
The T-LINK accounts table and data encryption keys are stored in the local database
NOTE: The SG-DRL5-IP can only receive data from the following transmitters: TL150, TL250*, TL250DV, TL300*, TL300CF*,
GS3055*, GS3055-I, GS3055-ICF*, GS3060*, TL26X*, GS206X*, TL26XGS*, GS31XX, 3G2060(R)*,TL2603G(R)*, 3G3070*,
3G3070RF*, 3G3070CF*, TL2803G(R)*, 3G2080(R)*, TL280(R)*, 3G4000*, 3G4000RF*
* UL/ULC Listed, x = 0, 5.
2.2.2 Visual Verification
Visual Verification enables the system operator to view images and hear audio captured during an alarm event. The images (JPG) and audio (WAV)
files are sent via Ethernet to the SG-DRL5-IP where they are converted to films (AVI) for viewing on the SG-System 5 Console.
Data such as detector ID, zone ID, film type, file size, number of files in film and event time is available for each Visual Verification event.
2.3 Approvals
2.3.1 Industry Approvals
l
UL 1610 Central Station Burglar Alarm Units
l
UL 864 Standard for Control Units and Accessories for Fire Alarm Systems
l
CAN/ULC-S304-06 Signal Receiving Centre and Premises Burglar Alarm Control Units
l
CAN/ULC-S559-04 Equipment for Fire Signal Receiving Centres and Systems
l
EN60950-1:2006 Standard for Information Technology Equipment.
l
AS/NZS 60950.1:2003 Information Technology Equipment - Safety
l
CISPR22 Information Technology Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurements
l
EN50130-4 Immunity requirements for components of fire, intruder and social alarm systems
l
NIST validation certificate number 2913 for AES 128 bit encryption.
For UL listed installations, the equipment shall be installed in accordance with the requirements of NFPA72, NFPA70, UL827 and the authority having
jurisdiction.
SG-System 5 with SG-DRL5-IP Line Card is ULC listed for active communication channel security level A1 - A4 when used in conjunction with T-
Link TL250, T-Link TL300, TL260, TL260GS, GS2060, 3G2060(R),TL2603G(R), 3G3070(RF)(CF), TL2803G(R), 3G2080(R) and TL280(R) Inter-
net/Intranet and/or GSM-GPRS alarm communicators. For this type of application the supervision and encryption features have to be enabled.
For ULC Installations the equipment shall be installed in accordance with the requirements of ULC-S561 and ULC-S301 Standards and the authority
having jurisdiction. The receiver can be used also in conjunction with ULC listed passive communication systems based on the configuration of the sys-
tems at the protected premises.
S
G
-S
ys
te
m
5
O
pe
ra
ti
ng
M
anua
l
Содержание SG-System 5
Страница 68: ...6 0 Options 68 Automation Mode Diagrams FIGURE 6 1 Flow Diagram for Loop Mode 0 SG System 5 Operating Manual ...
Страница 69: ...6 0 Options 69 FIGURE 6 2 Flow Diagram for Fallback Mode 1 SG System 5 Operating Manual ...
Страница 70: ...6 0 Options 70 FIGURE 6 3 Flow Diagram for All Mode 2 SG System 5 Operating Manual ...
Страница 71: ...6 0 Options 71 FIGURE 6 4 Flow Diagram for IP Fallback Mode 3 SG System 5 Operating Manual ...