Appendix D: Events & Messages
- 94 -
Description/Event
Automation message
Printer Message
Local Programming End via LCD
Where xx is the user number, and NAME is the pro-
grammed user label string
001000[#0000|NLD00xx]
SG -01-000-0000-NLD00XX-User: NAME Local Programming
Ended
Manual Mode Message ACK By User NAME -
Name is the programmed user label string and
{printer message} is the message that was acknow-
ledged
No Automation Message
SG -01-sss-AAAA--01/00-0000- {Printer Message} -Acknow-
ledged by User NAME
SG-CPM5 1 Auxiliary CPU Failure
001000[#0000|NYX0003] SG -01-000-0000-NYX0003-Primary CPM Auxiliary CPU Failure
SG-CPM5 2 Auxiliary CPU Failure
001000[#0000|NYX0004]
SG -01-000-0000-NYX0004-Secondary CPM Auxiliary CPU Fail-
ure
Temp 1 Warning
001000[#0000|NKSss01]
SG -01-000-0000-NKSss01-Primary CPM TEMP WARNING
Temp 1 Alarm
001000[#0000|NKAss01]
SG -01-000-0000-NKAss01-TEMP 1 ALARM
Temp 1 Restore
001000[#0000|NKJss01]
SG -01-000-0000-NKJss01-TEMP 1 RESTORE
Temp 2 Warning
001000[#0000|NKSss02]
SG -01-000-0000-NKSss21-Primary CPM TEMP WARNING
Temp 2 Alarm
001000[#0000|NKAss02]
SG -01-000-0000-NKAss02-TEMP 2 ALARM
Temp 2 Restore
001000[#0000|NKJss02]
SG -01-000-0000-NKJss02-TEMP 2 RESTORE
LCD 1 Absent
001000[#0000|NAT0200]
SG -01-000-0000-NAT0200-UIB 1 Cable Failed
LCD 1 Restore
001000[#0000|NAR0200]
SG -01-000-0000-NAR0200-UIB 1 Cable Restored
LCD 2 Absent
001000[#0000|NAT0300]
SG -01-000-0000-NAT0300-UIB 2 Cable Failed
LCD 2 Restore
001000[#0000|NAR0300]
SG -01-000-0000-NAR0300-UIB 2 Cable Restored
SG-PSU5 1 Fan Failure
001000[#0000|NYP0000]
SG -01-000-0000-NYP0000-PSU1 Fan Failed
SG-PSU5 1 Fan Restore
001000[#0000|NYQ0000]
SG -01-000-0000-NYQ0000-PSU1 Fan Restored
SG-PSU5 2 Fan Failure
001000[#0000|NYP0001]
SG -01-000-0000-NYP0001-PSU2 Fan Failed
SG-PSU5 2 Fan Restore
001000[#0000|NYQ0001]
SG -01-000-0000-NYQ0001-PSU2 Fan Restored
Volatile Memory Failure
001000[#0000|NIAss00]
SG -01-000-0000-NIAss00-Volatile Memory Failed
Expansion EMMC Failure
001000[#0000|NIAss01]
SG -01-000-0000-NIAss01-Non Volatile Memory Failed
SD Card Failure
001000[#0000|NIAss02]
SG -01-000-0000-NIAss02-SD Memory Failed
SD 90% Full
001000[#0000|NJLss02]
SG -01-000-0000-NJLss02-SD Memory 90% full
SD 100% Full
001000[#0000|NJOss02]
SG -01-000-0000-NJOss02-SD Memory 100% full
SD Card Formatted - From the console
001000[#0000|NRTss02]
SG -01-000-0000-NRTss02-SD Memory FORMATTED
Firmware Update Start
001001[#0000|NMIss00]
SG -01-001-0000-NMIss00- Firmware Update Initiated
Firmware Update Failed
001001[#0000|NMIss01]
SG -00-001-0000-NMIss01- Firmware Update Failed
SG-CPM5 Primary RTC Battery Trouble Restore
001000[#0000|NYR0110] SG -01-000-0000-NYR0110-Primary CPM RTC Battery Restored
SG-CPM5 Primary RTC Battery Trouble
001000[#0000|NYT0110]
SG -01-000-0000-NYT0110- Primary CPM RTC Battery Failed
SG-CPM5 Secondary RTC Battery Trouble restore
001000[#0000|NYR0210]
SG -01-000-0000-NYR0210-Secondary CPM RTC Battery
Restored
SG-CPM5 Secondary RTC Battery Trouble
001000[#0000|NYT0210] SG -01-000-0000-NYT0210- Secondary CPM RTC Battery Failed
Printer test
Not Applicable
SG -01-000-0000-Printer Test Message
COLDBOOT was performed by User via Console
001000[#0000|NYE0100]
SG -01-000-0000-NYE0100-COLDBOOT by CONSOLE
COLDBOOT was performed by User via LCD
001000[#0000|NYE0100]
SG -01-000-0000-NYE0100-COLDBOOT by LCD
User performed manual automation test message
from LCD.
001000[#0000|NRX0000]
No Printer message
S
G
-S
ys
te
m
5
O
pe
ra
ti
ng
M
anua
l
Содержание SG-System 5
Страница 68: ...6 0 Options 68 Automation Mode Diagrams FIGURE 6 1 Flow Diagram for Loop Mode 0 SG System 5 Operating Manual ...
Страница 69: ...6 0 Options 69 FIGURE 6 2 Flow Diagram for Fallback Mode 1 SG System 5 Operating Manual ...
Страница 70: ...6 0 Options 70 FIGURE 6 3 Flow Diagram for All Mode 2 SG System 5 Operating Manual ...
Страница 71: ...6 0 Options 71 FIGURE 6 4 Flow Diagram for IP Fallback Mode 3 SG System 5 Operating Manual ...