6.0 Options
- 72 -
FIGURE 6-5: Flow Diagram for Auto IP Fallback(4)
Option [402]: COM1 (Automation) Baud Rate
Default (9600)
Determines the baud rate at which the SG-CPM5 communicates to the automation software via serial automation port. Valid selections are: 1200, 2400,
4800, 9600, 19200, 38400, or 57600.
NOTE: The unit must be reset before parameter changes take effect.
Option [403]: COM1 Data Bits
Default (8)
Determines the number of data bits used to communicate to the automation software via serial automation port. Valid selections are: 7 or 8.
NOTE: The unit must be reset before parameter changes take effect.
Option [404]: COM1 Parity
Default (0) - None
Determines the parity of the automation serial port.
Numeric Setting Display
Description
0
None no parity (default)
1
Odd
odd parity
2
Even
even parity
NOTE: The number of stop bits cannot be changed and is always 2.
NOTE: The unit must be reset before parameter changes take effect.
Option [408]: Receiver Number
Default (01)
This is used to identify the receiver when communicating to the TCP/IP automation, serial automation and the printer. To change the receiver number,
enter a hexadecimal number from "01" to "FE." Receiver Number applies to all traffic unless overridden by other options.
S
G
-S
ys
te
m
5
O
pe
ra
ti
ng
M
anua
l
Содержание SG-System 5
Страница 68: ...6 0 Options 68 Automation Mode Diagrams FIGURE 6 1 Flow Diagram for Loop Mode 0 SG System 5 Operating Manual ...
Страница 69: ...6 0 Options 69 FIGURE 6 2 Flow Diagram for Fallback Mode 1 SG System 5 Operating Manual ...
Страница 70: ...6 0 Options 70 FIGURE 6 3 Flow Diagram for All Mode 2 SG System 5 Operating Manual ...
Страница 71: ...6 0 Options 71 FIGURE 6 4 Flow Diagram for IP Fallback Mode 3 SG System 5 Operating Manual ...