Conversion Between MicronNav Responder and Transponder
MicronNav System
0656-SOM-00001-07
136
© Tritech International Ltd.
Confirm the settings and close the setup page.
This completes the conversion to Transponder mode. Position the Transponder unit near the
USBL Transducer will confirm operation and "Ping T1 ok" should be displayed at the top-
right of the MicronNav window.
Note
If not already done so, delete the
Seanet Pro Supervisor
shortcut from the
desktop before standard use of Seanet Pro
11.3. Conversion to Responder
The Transponder unit can be reconfigured to Responder mode by clicking on the
Action
arrow button in the
MINIMODEM
row followed by
Setup
from the sub-menu to display the
AM100 ModemCfgSetup
page.
Change the
Unit OpMode
to
Responder
,
ID Bits
to
IdM0
, and enable the
COM Rx TMO
Enabled
check-box (as shown below).