Using the External Computer Data Link
MicronNav System
0656-SOM-00001-07
109
© Tritech International Ltd.
7.2.1. Proc XYZ
The ‘Proc XYZ’ data message contains the World X,Y & Z co-ordinate position of the
Responder/Transponder. The output message will include a message header and be in the
following format, in accordance with the proprietary RemV4 output protocol.
“%D” + SlotRe ‘Proc XYZ’ Nav Data Str <CR><LF>
SlotReplyHdr Data Structure (sent in hexadecimal format)
Data Description
Data Range Data Types
Total Number of Bytes in Message in Hex (including Command and
Reply codes)
NB
CARDINAL
Slot Number (range “01” to “0C” )
SlotN
SLOTN
Generic Device Type
SourceTypes SOURCEN
Data Reply Mode (0=ASCIIText, 1=Hex, 2=Binary, 3=CSV)
0,1,2 or 3
DIGIT
Send SeaKing Long = 3*, Send SeaKing Short = 2*, Send Raw data =
1, Send Processed Data = 0 (*Not applicable)
0,1,2 or 3
DIGIT
Example:
Byte Count = Hex 0049 (73)
Slot = 08 = MicronNav
Sourcetype = 32(Hex 20) = Null (not defined for MicronNav)
Data reply mode is ASCIIText
Send data = 0 = Proc XYZ
ALWAYS Hex e.g., “0049082000”