A ppend
i
x C - 7 2 0 0 Remote Mon
i
tor and Contro
l
Protoco
l
C G-6 0 4 2 (Rev. F, June 2 0 0 0)
C - 4
4.3 E
rr
o
r
Cod
e
s
(
a
t End of
Re
qu
e
st/Comm
a
nd
Re
spons
e
)
0 0 0
No error: Request/Command comp
l
eted successfu
ll
y.
0 0 1
Last Request/Command rece
i
ved successfu
ll
y; a w a
i
t
i
ng further
i
nput.
1nn
Inva
li
d data
i
n f
i
e
l
d nn on th
i
s
li
ne. F
i
e
l
d 0
i
s a
l
w ays the checksum f
i
e
l
d. If
there
i
s no checksum, the f
i
rst f
i
e
l
d
i
s f
i
e
l
d 1. In most cases, f
i
e
l
d 1
i
s the
Request/Command. In the case of mu
l
t
ili
ne
i
nput (0 0 1 > prompt), the checksum
i
s f
i
e
l
d 0 (
i
f enab
l
ed) and the next f
i
e
l
d
i
s f
i
e
l
d 1, etc. Inva
li
d data means
e
i
ther that the data makes no sense for the f
i
e
l
d
i
n quest
i
on (Examp
l
e: non-
numer
i
c str
i
ng w here number
i
s expected), the data
i
s out of range, or the data
i
s
i
nva
li
d.
1 0 0
Ind
i
cates checksum fa
il
ure. If there are extra f
i
e
l
ds
i
n the
i
nput, that f
i
e
l
d w
ill
be
f
l
agged as
i
nva
li
d data.
2 0n
Secur
i
ty v
i
o
l
at
i
on: Insuff
i
c
i
ent secur
i
ty
l
eve
l
to comp
l
ete command.
n
i
nd
i
cates the requ
i
red
l
eve
l
: 2 = operator or 3 = superv
i
sor.
3 0 0
Cou
l
d not comp
l
ete mot
i
on command because of A C U/dr
i
ve fau
l
t(s).
3 0 1
Inte
l
sat e
l
ements fa
il
ed 1 7 0-hour ver
i
f
i
cat
i
on.
3 0 2
Cou
l
d not update po
i
nt
i
ng command because contro
ll
er
i
s not current
l
y track
i
ng the
Immed
i
ate target A ND
i
n
Mov
e
to
l
oo
k
a
ng
l
e
s...
mode.
3 0 3
Exp
i
red tab
l
e: A
ll
records exp
i
red
3 0 4
Empty tab
l
e: No records ex
i
st
4.4 Ch
eck
sums
The 7 2 0 0 A C U remote supports an opt
i
ona
l
i
nput/output checksum feature that can be
enab
l
ed/d
i
sab
l
ed e
i
ther at the front pane
l
or at a remote stat
i
on us
i
ng the C 1 0 2
command. Refer to Sect
i
on 5.0. If checksums are enab
l
ed, the 7 2 0 0 A C U transm
i
ts a
checksum before each
li
ne of output and expects a checksum before each
li
ne of
i
nput.
If checksums are enab
l
ed, the genera
l
I/O format becomes:
M/C sends: cc text(CR)
A C U sends: [(ne w
li
ne)cc text]
(ne w
li
ne)cc nnn >
w here cc = checksum.
Содержание VertexRSI 7200
Страница 15: ...INTRODUCTION 1 4 THIS PA GE INTENTIONALLY LEFT BLANK...
Страница 21: ...O VERVIEW 2 6 Figure 2 3 7200 A CU Functional Block Diagram...
Страница 22: ...O VERVIEW 2 7 Figure 2 4 7200 Antenna Control Unit Top View Figure 2 5 7200 Antenna Control Unit Side View...
Страница 41: ...O VERVIEW 2 26 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 46: ...THEORY 3 5...
Страница 138: ...7200 OPERA TION 5 70 THIS PA GE INTENTIONALLY LEFT BLANK...
Страница 154: ...7200 M AINTENANCE 7 2 THIS PA GE INTENTIONALLY LEFT BLANK...
Страница 156: ...7200 DRA WINGS 8 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 160: ...A CRONYMS ABBREVIATIONS A 4 THIS PA GE INTENTIONALLY LEFT BLANK...
Страница 164: ...7200 PASSW ORD PROTECTION B 4 THIS PA GE INTENTIONALLY LEFT BLANK...
Страница 202: ...Appendix C 7200 Remote Monitor and Control Protocol CG 6042 Rev F June 2000 C 38 THIS PA GE INTENTIONALLY LEFT BLANK...
Страница 258: ...7200 TROUBLESHOOTING G 12 THIS PA GE INTENTIONALLY LEFT BLANK...
Страница 259: ...VENDOR DA T A H 1 APPENDIX H VENDOR DATA This appendix contains the Sumitomo NTAC 2000 O M manual for the inverters...
Страница 260: ...7200 VENDOR DA T A H 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 262: ...7200 MENU TREE I 2 THIS PA GE INTENTIONALLY LEFT BLANK...
Страница 264: ...Technical Support J 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 266: ...Technical Support J 4 THIS PAGE INTENTIONALLY LEFT BLANK...