The VP 300 prompts * * * ALARM HAS BEEN GIVEN * * * to indicate an alarm test was
performed. To clear this error, at the @ prompt, type:
C H
◆
WARNING
◆
You must clear the Hardware Error Table to reset the VP 300 call-out feature or the VP
300 will not attempt to call the alarm number when a true alarm occurs. If the
HARDWARE ERROR Table shows other errors, refer to the Hardware Errors section in
this chapter.
☞
TE A also closes the Alarm Relay and turns ON the Alarm. C H reopens the Alarm
Relay and turns OFF the Alarm.
■
System Forwarding
The forwarding string entered in System Parameter 45 — SYSTEM-RELOAD FORWARD STRING,
is automatically dialed if the VP 300 reloads for any reason. During this time, calls are not accepted
for several minutes while an automatic check is performed on the database. If forwarding strings are
not set up, incoming calls receive a ring-no-answer condition until the system is ready. When
forwarding strings are set up correctly, the PBX forwards all incoming calls to an operator or attendant
for handling until the system is ready to receive calls. The following describes the procedure for
testing this feature.
To test the forward feature, at the @ prompt, enter:
TEST C 1 (or TE C 1)
This causes each port to attempt the forward string. When successful, a message is displayed. To
forward a specific port or range of ports, at the @ prompt, enter:
TE C 1 [X] [Y]
where X is the port number or the first port in a range of ports to forward, and Y is the last port in a
range of ports. If only one port is specified, the VP 300 attempts to forward only that port. If a range is
specified, the VP 300 attempts to forward all ports in the range. If no port is specified, the VP 300 tries
to forward all ports. If a port is successfully forwarded, it is left in the forward state. If a port fails to
complete the forward string, it is left in the NDT state. The VP 300 continues to try to forward all
ports specified until successful or
is pressed. To review the port status, use the PS
command. To cancel forwarding, run the System Initialization test.
■
System Initialization
When the VP 300 has reloaded and is ready to handle calls, an initialization sequence automatically
takes place. First, the PBX initialization string is attempted (System Parameter 33 — PBX
INITIALIZE CODE), then the cancel forward string is attempted (System Parameter 46 — SYSTEM-
RELOAD CANCEL FORWARD-STRING) for each port in turn. When a port fails to complete the
initialization string or the cancel forward string, the port is left in the NDT state. The system attempts
every ten seconds to initialize a port.
To test this feature, at the @ prompt enter:
Escape
Enter
Enter
Enter
Toshiba VP Systems Release 7.1
July, 1994
5-24
Installation and Maintenance Manual
Содержание VP 300
Страница 2: ......
Страница 10: ......
Страница 14: ......
Страница 19: ...Quick Reference Guide Hardware Toshiba VP 300 System Specifications Toshiba VP Systems Release 7 1 July 1994 ...
Страница 20: ...Toshiba VP Systems Release 7 1 July 1994 ...
Страница 52: ...Toshiba VP Systems Release 6 1 February 1993 2 14 Installation and Maintenance Manual ...
Страница 56: ...Toshiba VP Systems Release 7 1 July 1994 ...
Страница 146: ......
Страница 312: ...Toshiba VP Systems Release 7 1 July 1994 ...
Страница 314: ......
Страница 444: ......
Страница 496: ......
Страница 542: ......
Страница 598: ...Toshiba VP Systems Release 6 1 February 1993 ...
Страница 600: ...Toshiba VP Systems Release 6 1 February 1993 ...