GTCOM2 User manual
42 |
E N
The module could be controlled only by these users, whose phone numbers entered in the memory of the module
Figure 68 Users/ Access control window
6.7
Reporting SMS&Dial in Case of Alarm Events
The system supports up to 8 user phone numbers identified as User 1 through 8 for monitoring purpose: receive alarm phone calls via GSM
connection and SMS text messages from the system. When the system is armed or disarmed by free of charge phone call or SMS text message, the
system sends a confirmation by SMS text message to user phone number that the system arming/disarming.
By default, once a user phone number is listed, the system ignores any incoming calls and SMS text messages from a non-listed phone number
as well as it rejects the SMS text messages containing wrong SMS password even from a listed user phone number. To permit/deny system
arming/disarming by phone call and SMS text message that contain a valid SMS password, configuration by SMS text message that contain a valid SMS
password from any phone number, please refer to the following configuration methods.
The system will NOT transmit any data to monitoring station while configuring the system remotely via GPRS network. However, during
the remote connection session, the data messages are queued up and transmitted to the monitoring station after the configuration
session is over. SERA2 software provides remote system configuration ability via Internet using TCP/IP server on SERA2 software. The
connection can be established on the system via GPRS network. After the remote system configuration is complete the session will
automatically expire in 20 minutes. Alternatively, the connection with the server can be terminated at any time by sending an SMS text
message
NEVER add a phone number of the device’s SIM card as a user phone number!
6.7.1
Reporting to the user‘s mobile phone
GSM Communications > SMS DIAL Reporting
The SMS DIAL Reporting
settings let you enter user’s phone numbers and set
events that will be reported to the user
When a zone or tamper is violated, depending on zone, the system will cause an alarm. During the alarm, the system will follow this pattern:
1. The system activates the siren/bell. The siren/bell will emit pulsating sound if the violated zone is of Fire type, otherwise the sound will be steady.
2. The system attempts to send an SMS text message (if programmed), containing the violated name. The system will send SMS text messages regarding
each violated zone separately.
a) If the user phone number is unavailable, it will attempt to send the SMS text message to the next listed user phone number, assigned to the same zone
as the previous one. The user phone number may be unavailable due to the following reasons: mobile phone was switched off or was out of GSM signal
coverage.
b) By default, the system will continue sending the SMS text message to the next listed user phone numbers in the priority order. The system try to send
the SMS text message as many times as programmed.