Remote control and configuration using SMS Commands
Users allowed:
Installers allowed:
Control outputs,
Control outputs
Arm/disarm the system or select stay, sleep mode
Arm/disarm the system or select stay, sleep mode
Bypass zones
Bypass zones
Set the time of the module
Set the time of the module
Request zone test and system state
Request zone test and system state
Forward messages to other number
Forward messages to other number
Enter/ deleting user phone numbers
Set periodical test,
Set GPRS network settings
Remote control via Internet
Activate/ deactivate connection to the remote control server.
Enter/ deleting iButton keys
Change sensor’s values
Request module configuration information
Change user, installer password
Installer code
– 6-digit password used for system configuration, control and request for information. By default, installer code is 000000, which is
highly recommended to change.
User code
– 6-digit password used for system control and request for information. By default, installer code is 000000, which is highly recommended
to change.
The module could be controlled only by these users, whose phone numbers entered in the memory of the module
- Identification:
INST – Install used for module’s configuration.
- Installer’s or user’s password.
- space character
- Command code.
- space character
- First configuration array
- space character
- Second configuration array
- etc.
- Identification:
USER – User used for module’s control.
- Installer’s or user’s password.
- space character
- Command code.
- space character
- First configuration array
- space character
- Second configuration array
- etc.
10 The table of installers commands
SMS commands with
correct INST password
can be send from any phone number. Keep INST password in secret!
SMS configuration is allowed only with Latin characters. Unicode is not allowed.
Table 8 The table of installers commands
INST000000˽001˽N#TEL#SMS#DIAL#System
open close
Programming of users telephone numbers to send SMS and to make a call if the event
occur:
001= programming user‘s tel. numbers for DIAL and send SMS
N = user ID number 1-8
TEL = user‘s telephone number (max 16 digits) without (+) country code, operator‘s code and user‘s
telephone number included. The end symbol #;
SMS = event filter for sms. 1- send event, 0-
don’t send event. Sequence of the events 1.2.3...n For
example: 001000
DIAL = event filter for DIAL. 1-DIAL if the event occur, 0-
don‘t DIAL Sequence of the events
1.2.3...n For example: 101000
#= delimiter
e.g.: INST000000 001 1#37066666666#0001000000#0000011111#
Event filter eiliskumas:
1-reserved
2-system open close
............
...........
10-Input/Zone4 Alarm/Restore
INST000000˽002˽ID
Delete user’s phone number according the
user ID number
. Phone number used for receive
user’s information.
002= command code (deleting user‘s numbers according the user ID number)
ID = user ID number from 1 to 8
INST000000 004 ID#TEL#OUT#OPT#NAME#
To enter user‘s telephone number for remote control via short call