GTCOM2 User manual
10 |
E N
GTCOM2 communicator supports RING/TIP interface communication wiring method. RING/TIP interface
– The alarm panel is linked up with GTCOM2
communicator via the RING and TIP terminals simulating the connectivity of the PSTN line.
RING/TIP interface
– Retrieves Ademco Contact ID data from the alarm panel, converts it into user-understandable text and delivers to up to 8 listed
users by SMS text message.
GTCOM2 has 2 on-board digital inputs (normally closed or
normally open) for alarm device’s PGM output or detection
device connection, such as magnetic door contact. By
connecting the input to a non-2G/3G/4G LTE alarm
panel’s PGM output, up to 8 listed user phone numbers
will be able to receive an SMS text message, app
notifications as well as to notify the monitoring station
regarding arming/disarming and other events depending
on the alarm panel configuration.
The outputs can also be used for arming/ disarming by
connecting an output to one of the alarm panel’s zones
pre-configured as a keyswitch.
If the control panel status changes from ARM to
DISARM, the status of GTCOM2 changes from ARM to
DISARM also
If the siren is triggered, the SMS will be send to the
user’s mobile followed by a call
GTCOM2 could be used for all control panel control,
gate control. The second keyswitch can be used to stay
ARM.
The first keyswitch could be used for arm the first partition and the second keyswitch can be used for arm the second partition
You have to select:
1.
ARM 2 partitions at the same time remotely
2.
ARM stay remotely or
3.
ARM only 1 partition remotely
Alarm Panel and GTCOM2 synchronization
Connect remotely to your primary alarm panel remotely
from anywhere
at anytime.
It is possible:
- To control primary alarm panel from GTCOM2 and see the status in
app
- To control GTCOM2 from primary alarm panel and see the status in
keyboard.
GTCOM2 module may be used in remotely connecting other security system. The security system should have input to arm/disarm the security system.
For this purpose selected GTCOM output should be connected to the input of the security system
Figure 11 ARM/ DISARM the panel via keyswitch zone
Figure 10Communicator wiring diagram