5.10 Measurement auxiliary setting
5-26
■
Comet setting
When the quarter bridge 3-wire method is used for measuring strain, this setting allows
compensation of unnecessary factor error caused by lead wire and strain error caused when
the input value is large. This function is called “Comet”. Refer to “10.3: Complete
Compensation Method of Strain (Comet)” for more detail about Comet.
■
Power source frequency of measurement environment
Set a commercial power source frequency of the region where you are using the TC-32K.
This setting may prevent variation or shift when the measurement value is unstable.
1. Move the cursor (reversed indication)
with
[▲][▼]
keys on the “Setting
concerning measurement” screen and
press
[ENT]
key, or press
[2]
of ten
keys, to go to “Comet”.
2. Move the cursor either to
“Non”, ”CometA” or “CometB” with
[
◄][►]
keys, and press [
ENT]
key.
When the sensor mode is quarter bridge 3-wire method, a value compensated
by the non-linear correction is displayed even if you select [Non]. By
selecting Comet, you can acquire more accurate strain value.
Note
1. Move the cursor (reversed indication) with
[▲][▼]
keys on the “Setting concerning
measurement” screen and press
[ENT]
key,
or press
[3]
of ten keys, to go to “Power
frequency”.
2. Move the cursor either to “50Hz” or
“60Hz” with
[
◄][►]
keys, and press [
ENT]
key.
Содержание TC-32K
Страница 1: ...O p e r a t i o n M a n u a l TC 32K HANDHELD DATA LOGGER...
Страница 8: ...Chapter 12 Error Message 12 1 Explanations and countermeasures for error messages 12 2...
Страница 9: ...Chapter 1 Overview 1 1 Overview 1 2 1 2 Features 1 2 1 3 Details about each part 1 3...
Страница 22: ...2 5 Operation outline 2 10 memo...
Страница 23: ...Chapter 3 Sensor Connection 3 1 Sensor connection 3 2...
Страница 65: ...5 10 Measurement auxiliary setting 5 28 memo...
Страница 78: ...6 5 Recording in data memory and CF card 6 13 memo...
Страница 86: ...7 7 Remote measurement 7 8 memo...
Страница 98: ...8 7 Factory setting 8 12 memo...
Страница 127: ...11 4 Outside drawing 11 8 11 4 Outside drawing Unit mm...
Страница 128: ...Chapter 12 Error Message 12 1 Explanations and countermeasures for error messages 12 2...