PK-232 – MBX OPERATING MANUAL
COMMAND SUMMARY
4/91
A-38
163
Command names are shown with UPPER-CASE letters indicating the minimum number of charac-
ters required for the command. The lower-case letters indicate the (optional) rest of the command
name.
DW
ait "n"
Default: 16 (160 msec.)
Mode: Packet
Host: DW
Parameters:
"n" -
0 to 250 specifies wait time in ten-millisecond intervals.
Unless the PK-232 is waiting to transmit digipeated packets, DWAIT forces your PK-232 to pause
DWAIT x 10 mSec after last hearing data on the channel, before it begins its transmitter keyup se-
quence.
DWAIT is an older way collisions with digipeated packets were avoided. These days the P-PERSIS-
TENT method is generally used. When the PPERSIST command is ON (default) the DWAIT timer is
ignored.
EAS
ON|OFF
Default: OFF
Mode: Baudot, ASCII, AMTOR and MORSE Host: EA
Parameters:
ON -
Echo characters when actually sent on the air by the PK-232.
OFF - Echo characters when sent to the PK-232 by the computer.
The ECHO-AS-SENT (EAS) command functions in all modes except packet. EAS lets you to choose
the way data is displayed on your monitor screen or printer. To display your typing exactly as you
are typing the keyboard characters or sending from a disk file, set EAS "OFF" (default). To see the
actual data being sent from your PK-232 to your radio and transmitted on the air, set EAS "ON".
When EAS is ON in Morse and Baudot RTTY, you'll see only UPPER CASE characters on your screen
- the data actually transmitted to the distant station.
If EAS is ON in AMTOR Mode A (ARQ), you'll see characters echoed on your screen only after the
distant station has validated (Ack'd) your block of three characters. For Packet the MXMIT com-
mand should be used.
Nulls ($00) are not echoed, including the nulls produced by DIDDLE ON in ASCII.
E
cho ON|OFF
Default: ON
Mode: All
Host: EC
Parameters:
ON -
Characters received from the terminal ARE echoed by the PK-232.
OFF - Characters are NOT echoed.
The ECHO command controls local echoing by the PK-232 when in Command or Converse Mode.
Local echoing is disabled in Transparent Mode.
o
Set ECHO ON (default) if you don't see your typing appear on your display.
o
Set ECHO OFF if you see each character you type doubled.
ECHO is set correctly when you see the characters you type displayed correctly.
Содержание PK-232MBX
Страница 1: ...PK 232 MBX Operating Manual MODEL PK 232MBX DATA CONTROLLER Timewave Technology Inc...
Страница 212: ...PK 232 MXB OPERATING MANUAL SCHEMATICS B 1 212...
Страница 213: ...PK 232 MXB OPERATING MANUAL SCHEMATICS B 2 213...
Страница 214: ...PK 232MBX OPERATING MANUAL PARTS PICTORAL 4 91 C 1 214 APPENDIX C PARTS PICTORIAL DISPLAY BOARD...
Страница 222: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 6 222...
Страница 223: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 7 223...
Страница 224: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 8 224...
Страница 225: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 9 225...
Страница 226: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 10 226...