PK-232 – MBX OPERATING MANUAL
COMMAND SUMMARY
4/91
A-11
136
The following are the recommended command settings for Priority Acknowledge:
1200 baud VHF Packet
300 baud HF Packet
ACKPRIOR ON
ACKPRIOR ON
PPERSIST ON
PPERSIST ON
PERSIST 84
PERSIST 84
SLOTTIME 30
SLOTTIME 8
RESPTIME 0
RESPTIME 0
MAXFRAME 1 - 7
MAXFRAME 1
FRACK 8
FRACK 15
HBAUD 1200
HBAUD 300
VHF ON (or TONE 3)
VHF OFF (or TONE 0)
DWAIT doesn't matter
DWAIT doesn't matter
Stations using neither the Priority Acknowledge nor the P-persistence schemes should set DWAIT
73 for 1200 baud and DWAIT 76 for 300 baud work. Stations using P-persistence but not Priority
Acknowledge should set PERSIST and SLOTTIME to the same values that ACKPRIOR stations are
using.
Timewave and TAPR use some different command names to handle P-persistence. The following
table should help with the AEA/TAPR command differences:
TAPR_SLOTS
MFJ SLOTMASK
AEA_PERSIST
Remarks
1
$00
255
Disables slotting
2
$01
127
3
84
4
$03
63
Default setting
6
42
8
$07
31
Very busy channel
12
20
16
$0F
15
Extremely busy channel
64
$3F
3
Timewave products calculate the TAPR ACKTIME value based on the setting of HBAUD.
The TAPR DEADTIME command is analogous to the Timewave SLOTTIME command.
ACRD
isp "n"
Default: 0
Mode: ALL
Host: AA
Parameters:
"n" -
0 to 255 specifies the screen width, in columns or characters.
0 (zero) disables this function.
The numerical value "n" sets the terminal output format for your needs. Your PK-232 sends a
<CR><LF> sequence to your computer or terminal at the end of a line in the Command and Con-
verse Modes when "n" characters have been printed. Most computers and terminals do this auto-
matically so ACRDISP defaults to 0.
When the PK-232 is in the MORSE mode, received data will be broken up on word boundaries if
possible. At a column of 12 less than the ACRDISP value, the PK-232 starts looking for spaces in
the received data. The first space received after this column forces the PK-232 to generate a car-
riage return. If ACRDISP is 0 (default), this occurs at column 60. If there are no spaces at or after
this column then a carriage return occurs at ACRDISP.
Содержание PK-232MBX
Страница 1: ...PK 232 MBX Operating Manual MODEL PK 232MBX DATA CONTROLLER Timewave Technology Inc...
Страница 212: ...PK 232 MXB OPERATING MANUAL SCHEMATICS B 1 212...
Страница 213: ...PK 232 MXB OPERATING MANUAL SCHEMATICS B 2 213...
Страница 214: ...PK 232MBX OPERATING MANUAL PARTS PICTORAL 4 91 C 1 214 APPENDIX C PARTS PICTORIAL DISPLAY BOARD...
Страница 222: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 6 222...
Страница 223: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 7 223...
Страница 224: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 8 224...
Страница 225: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 9 225...
Страница 226: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 10 226...