PK-232 – MBX OPERATING MANUAL
COMMAND SUMMARY
4/91
A-23
148
CAS
edisp "n"
Default: 0 (as is)
Mode: Packet
Host: CX
Parameters:
"n" -
0 to 2 specifies how your PK-232 sends characters to your terminal.
CASEDISP allows you to set the case of the characters your PK-232 sends to your terminal. CASE-
DISP offers three possible modes:
CASEDISP 0 "As is" - characters are not changed.
CASEDISP 1 "lower" - all characters are displayed in lower case only.
CASEDISP 2 "UPPER" - all characters are displayed in upper case only.
CASEDISP has no effect on your transmitted data.
CB
ell ON|OFF
Default: OFF
Mode: Packet/AMTOR
Host: CU
Parameters:
ON -
Three BELL characters <CTRL-G> ($07) are sent to your terminal with the
"*** CONNECTED to or DISCONNECTED from (call sign)" message.
OFF - BELLS are NOT sent with the CONNECTED or DISCONNECTED message.
Set CBELL ON if you want to be notified when someone connects to or disconnects from your sta-
tion in Packet, or upon establishing a link in AMTOR.
CF
rom all,none,yes/no call1[,call2..] Default: all
Mode: Packet
Host: CF
Parameters:
call -
all, none, YES list, NO list.
List of up to 8 call signs, separated by commas.
CFROM determines how your PK-232 responds to connect requests from other stations. CFROM is
set to "all" when you first start your PK-232.
To reject all call requests, type CFROM NONE. Your PK-232 sends the calling station a DM packet,
or "busy signal".
To accept calls from one or more specific stations, type CFROM YES (followed by a list of calls
signs). Connects will be accepted from stations whose call signs are listed after CFROM YES. For
example:
cmd:cfrom yes WX1AAA,WX2BBB,WX3CCC,WX4DDD
To reject calls from one or more specific stations, type
CFROM NO
(followed by a list of call signs).
Connect requests will be ignored from stations whose call signs are listed after CFROM NO.
You can include optional SSIDs specified as "-n" after the call sign. If CFROM is set to "no W2JUP",
connect attempts from all SSIDs of W2JUP (W2JUP-0 through W2JUP-15) will be ignored. If
CFROM is set to "yes W2JUP-1", then only W2JUP-1 will be allowed to connect. Clear CFROM with
"%" "&" or "OFF" as arguments.
Содержание PK-232MBX
Страница 1: ...PK 232 MBX Operating Manual MODEL PK 232MBX DATA CONTROLLER Timewave Technology Inc...
Страница 212: ...PK 232 MXB OPERATING MANUAL SCHEMATICS B 1 212...
Страница 213: ...PK 232 MXB OPERATING MANUAL SCHEMATICS B 2 213...
Страница 214: ...PK 232MBX OPERATING MANUAL PARTS PICTORAL 4 91 C 1 214 APPENDIX C PARTS PICTORIAL DISPLAY BOARD...
Страница 222: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 6 222...
Страница 223: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 7 223...
Страница 224: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 8 224...
Страница 225: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 9 225...
Страница 226: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 10 226...