Unconnected packets are sent as Unnumbered I-frames (UI frames) with the destination and digi-
peat fields taken from "call1' through "call9' options. When a destination is not specified, uncon-
nected packets are sent to "CQ" .
Unconnected packets sent from other packet stations can be monitored by setting MONITOR to a
value greater than "1" and setting MFROM to ALL.
The UNPROTO path and address is also used for beacon packets.
US
ers "n"
Default: 1
Mode: Packet
Host: UR
Parameters:
"n" - 0 to 10 specifies the number of active simultaneous connections that can be
established with your PK-232.
USERS affects the way that incoming connect requests are handled. It does not affect the number
of connections you initiate with your PK-232. For example:
USERS 0
allows incoming connections on any free logical channel
USERS 1
rejects incoming connections if there are connections on 1 or more logical
channels.
USERS 2
rejects incoming connections if there are connections on 2 or more logical
channels. And so on, through USERS 10.
USO
s ON|OFF
Default: OFF
Mode: Baudot RTTY
Host: US
Parameters:
ON -
Letters (LTRS) case IS forced after receiving a space character.
OFF - Letters (LTRS) is NOT forced after receiving a space character.
Use the USOS Command (UnShift On Space) when you want your PK-232 to automatically change
from figures to letters after receiving a space character.
When using Baudot RTTY in poor HF receiving conditions, a received character can be incorrectly
interpreted as a FIGURES-SHIFT character, forcing the received data into the wrong case. Many
otherwise good characters received after this will be interpreted as figures (numbers and punctua-
tion), not as the letters sent by the distant station. USOS ON helps reduce these receiving errors.
V
hf ON|OFF
Default: ON
Mode: Packet
Host: VH
Parameters:
ON -
Packet tones are shifted 1000 Hz.
OFF - Packet tones are shifted 200 Hz.
Use the VHF Command for immediate software control of the PK-232's modem tones. Changing
components or switch settings is not required.
Set VHF ON for VHF operation (default), and set VHF OFF for HF Packet operation.
NOTE:
Be sure to change HBAUD to 300 bauds when operating below 28 MHz.
Содержание PK-232MBX
Страница 1: ...PK 232 MBX Operating Manual MODEL PK 232MBX DATA CONTROLLER Timewave Technology Inc...
Страница 212: ...PK 232 MXB OPERATING MANUAL SCHEMATICS B 1 212...
Страница 213: ...PK 232 MXB OPERATING MANUAL SCHEMATICS B 2 213...
Страница 214: ...PK 232MBX OPERATING MANUAL PARTS PICTORAL 4 91 C 1 214 APPENDIX C PARTS PICTORIAL DISPLAY BOARD...
Страница 222: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 6 222...
Страница 223: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 7 223...
Страница 224: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 8 224...
Страница 225: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 9 225...
Страница 226: ...PK 232 MBX OPERATING MANUAL SPECIFIC RADIO CONNECTIONS 96 1 E 10 226...