49
UV Height Adjustment
1. Put a sample piece of material with a UV crayon mark under the UV sensor.
Note: A UV crayon mark will light up under the UV sensor.
2. Loosen the two bolts that hold the UV sensor to the pusher foot.
3. Adjust the sensor down until you get 3 separate circles on the UV mark.
Note: The size of these circles control how close together your marks can be.
4. Tighten the two bolts.
UV Sensitivity Adjustment
1. Mark a piece of material with a UV crayon.
2. The UV sensor has a yellow light that will light when the sensor is detecting a UV crayon mark.
3. Slide the material under the UV sensor and watch the light. It should only turn on when detecting
your crayon marks from step 1. If it doesn't detect the mark or if it detects something other than a
mark, continue to the next step.
4. Use the dial on the front of the sensor to adjust the sensor sensitivity.
5. Once adjusted, test again as described in step 3.
Infrared Length Sensor Adjustment
The IR length sensor has an adjustment for sensitivity. The height of the sensor cannot and should
not be changed.
IR Sensitivity Adjustment
The IR sensor has a yellow light that will light up when it senses something under it. It also has a
small dial that can adjust the sensitivity of the sensor.
Содержание TigerSaw 1000
Страница 1: ......
Страница 2: ......
Страница 8: ...5 TigerSaw Cap Guard TigerSaw Guard Back ...
Страница 9: ...6 TigerSaw Guard Sides ...
Страница 10: ...7 TigerSaw Blade Access Door In Feed and Out Feed Table ...
Страница 11: ...8 Pusher Foot ...
Страница 15: ...12 1 Assemble table legs ...
Страница 17: ...14 5 Attach the back fence to the out feed table 6 Attach the material staging tubes to the in feed table ...
Страница 24: ...21 7 Attach the Printer Stand M8 X 35 ...
Страница 66: ......
Страница 67: ......