204
-222 Data out of range;duty cycle; value clipped to ...
Example: The duty cycle is limited depending on the frequency.
Duty Cycle
Frequency
50%
> 25MHz
10%~90%
100 KHz ~ 1MHz
1%~99%
< 100KHz
-222 Data out of range; duty cycle limited by frequency; value clipped to upper
limit
Example: The duty cycle is limited depending on the frequency.
When the frequency is greater than 50 MHz, the duty cycle is
automatically limited to 50%.
-313 Calibration memory lost;memory corruption detected
Indicates that a fault (check sum error) has occurred with the
non-volatile memory that stores the calibration data.
-314 Save/recall memory lost;memory corruption detected
Indicates that a fault (check sum error) has occurred with the
non-volatile memory that stores the save/recall files.
-315 Configuration memory lost;memory corruption detected
Indicates that a fault (check sum error) has occurred with the
non-volatile memory that stores the configuration settings.
-350 Queue overflow
Indicates that the error queue is full (over 20 messages
generated, and not yet read). No more messages will be stored
until the queue is empty. The queue can be cleared by reading
each message, using the *CLS command or restarting the
function generator.
8-21-3.Query Errors
-410 Query INTERRUPTED
Indicates that a command was received but the data in the
output buffer from a previous command was lost.
-420 Query UNTERMINATED
The function generator is ready to return data, however there
was no data in the output buffer. For example: Using the APPLy
command.
-430 Query DEADLOCKED
Indicates that a command generates more data than the output
buffer can receive and the input buffer is full. The command will
fin
ish execution, though all the data won’t be kept.
8-21-4.Arbitrary Waveform Errors
-770 Nonvolatile arb waveform memory corruption detected
Indicates that a fault (check sum error) has occurred with the
non-volatile memory that stores the arbitrary waveform data.
-781 Not enough memory to store new arb waveform; bad sectors
Содержание FGX-2220
Страница 1: ...B71 0406 01 INSTRUCTION MANUAL ARBITRARY FUNCTION GENERATOR FGX 2220...
Страница 44: ...31 3 1 5 Selecting a Noise Waveform Panel Operation 1 Press the Waveform key Waveform 2 Press F5 Noise Noise F5...
Страница 98: ...85...
Страница 137: ...124...
Страница 227: ...214 9 2 External Dimensions Figure...
Страница 229: ...7F Towa Fudosan Shin Yokohama Bldg 2 18 7 Shin Yokohama Kohoku ku Yokohama Kanagawa 222 0033 Japan http www texio co jp...