138
8-5-2. SYSTem:REMote
Set
Description
Disables the front panel keys and puts the function generator
into remote mode
Syntax
SYSTem:REMote
Example
SYST:REM
8-6. Apply Commands
The APPLy command has 5 different types of outputs (Sine, Square, Ramp,
Pulse, Noise, ). The command is the quickest, easiest way to output waveforms
remotely. Frequency, amplitude and offset can be specified for each function.
As only basic parameters can be set with the Apply command, other parameters
use the instrument default values.
The Apply command will set the trigger source to immediate and disable burst,
modulation and sweep modes. Turns on the output commandOUTPut[1|2] ON.
The termination setting will not be changed.
As the frequency, amplitude and offset parameters are in nested square brackets,
amplitude can only be specified if the frequency has been specified and offset can
only be specified if amplitude has been set. For the example:
SOURce[1|2]:APPLy:SINusoid [<frequency> [,<amplitude> [,<offset>] ]]
Output Frequency For the output frequency, MINimum, MAXimum and DEFault
can be used. The default frequency for all functions is set to 1
kHz. The maximum and minimum frequency depends on the
function used. If a frequency output that is out of range is
specified, the max/min frequency will be used instead. A
“Data out range error will be generated” from the remote
terminal.
Содержание FGX-2220
Страница 1: ...B71 0406 01 INSTRUCTION MANUAL ARBITRARY FUNCTION GENERATOR FGX 2220...
Страница 44: ...31 3 1 5 Selecting a Noise Waveform Panel Operation 1 Press the Waveform key Waveform 2 Press F5 Noise Noise F5...
Страница 98: ...85...
Страница 137: ...124...
Страница 227: ...214 9 2 External Dimensions Figure...
Страница 229: ...7F Towa Fudosan Shin Yokohama Bldg 2 18 7 Shin Yokohama Kohoku ku Yokohama Kanagawa 222 0033 Japan http www texio co jp...