56
4-4-2. PM Carrier Waveform
Background
PM uses a sine wave as default. Noise and Pulse
waveform cannot be used with phase modulation.
Panel Operation
1.
Press the Waveform key.
Waveform
2.
Press F1 ~ F4 to select the
waveform.
Sine
F1
~
Ramp
F4
Range
Carrier Waveform
Sine wave, Square wave,
ramp wave.
4-4-3. PM Carrier Frequency
Selects the maxium carrier frequency for the carrier wavefrom. The default carrier
frequency is 1kHz.
Panel Operation
1.
Press the FREQ/Rate key to
select the carrier frequency.
FREQ/Rate
2.
The FREQ parameter will become highlighted in the
parameter window.
3.
Use the arrow keys and scroll
wheel or number pad to enter the
carrier frequency.
0
/
3
2
1
4
7
8
5
9
6
4.
Press F1~F5 to select the
frequency unit.
uHz
F1
~
MHz
F5
Range
Carrier Wave
Carrier Frequency
Sine wave
1
μHz~25MH
Square wave
1μHz~15MHz
Ramp wave
1μHz~1MHz
Default frequency
1 kHz