69 

Default 

The beeper is enabled when it is shipped from the factory. The beeper state is stored in 
a volatile memory and the default will be restored when the meter has been turned off or 
after a remote interface reset. 
 

How to control the beeper 

User can control the beeper from either the front panel operation or the remote interface 
operation.   
 

Front Panel Operation 

Follow the procedure below to disable or enable the beeper:

 

Press MENU button then use 

  and 

  buttons to find SYSTEM menu. Press

 

ENTER to choose it, and then again use 

  and 

  buttons to find BEEP menu. Press

 

ENTER to choose it, and then find ON or OFF 

by using 

  and 

  buttons. Press ENTER on your selection.

 

The locations of the buttons 

are shown with red rectangle frames in 

Figure 4-27

 
Procedures: MENU 

 SYSTEM 

 BEEP

 {ON|OFF} 

 

 

Figure 4-27 

 

Remote Interface Operation 

The following commands show how to use the remote interface operation to disable or 
enable the beeper: 
 

SYSTem:BEEPer 
SYSTem:BEEPer:STATe {OFF|ON} 

 

3.4.3    Reading Memory (Store & Recall) 

DL-2060  has  a  memory  capacity  of  2000  readings.  The  readings  are  stored  in 
first-in-first-out order and the memory type is volatile, which means the stored readings 
will be cleared when the multimeter is power-off. The reading memory feature can be 

 

 

 

Содержание DL-2060

Страница 1: ...B71 0110 41 INSTRUCTION MANUAL 6 1 2 DIGITAL MULTIMETER DL 2060 DL 2060G DL 2060VG DL 2060R DL 2060VR...

Страница 2: ...ENTS 25 2 5 CONTINUITY MEASUREMENTS 26 2 6 DIODE MEASUREMENTS 27 2 7 TEMPERATURE MEASUREMENTS 28 2 7 1 Thermocouple Measurements 28 2 7 2 RTD Measurements 29 2 7 2 1 2 Wire RTD Measurements 29 2 7 2 2...

Страница 3: ...E 97 5 1 ERROR TYPE 97 5 1 1 Execution Errors 97 APPENDIX 101 A SPECIFICATION LIST 101 B REMOTE INTERFACE REFERENCE 105 B 1 An Introduction to the SCPI Language 105 B 2 Output Data Formats 109 B 3 The...

Страница 4: ...show the warning and caution items required to safely use the product The following pictorial indication and warning character indication are provided Pictorial indication Some part of this product or...

Страница 5: ...xplained If the fuse is incorrectly replaced a fire may occur Changing the power supply voltage The product enables to change operational power supply voltage by switch over the inlet at rear panel Pl...

Страница 6: ...factory they may slightly change because of secular changes in its parts It is recommended to periodically calibrate the product so that it is used with its performance and specifications stable For...

Страница 7: ...tempt to operate the damaged product 1 1 1 Inspection Your product package is supplied with the following items Power line cord 1 Standard Test Leads 1 CD 1 User s Manual and software USB cable 1 Test...

Страница 8: ...I Taking off the handle from the Multimeter Step 1 Turn up the handle Pull slightly outward on both sides of the handle and slowly rotate it up as shown in Figure 1 1 Figure 1 1 Step 2 Pull out the ha...

Страница 9: ...ons to suit users needs Position 1 The default position is for packing as shown in Figure 1 3 Figure 1 3 Position 2 The adjusted position is for operation as shown in Figure 1 4 Figure 1 4 Position 3...

Страница 10: ...ltage setting may cause severe damage to your instrument Warning The power cord supplied with DL 2060 contains a separate ground wire for use with grounded outlets When proper connections are made ins...

Страница 11: ...Remove the red voltage setting selector from the right middle seam as shown in Figure 2 3 You might need a screwdriver to do so Figure 2 3 Step 4 Turn it over to 220V position as shown in Figure 2 4 F...

Страница 12: ...e instrument repeatedly blows fuses locate and correct the cause of the trouble before replacing the fuse Fuse to replace 250VT250mA Verify that the power line fuse is good Replace the fuse if it is d...

Страница 13: ...need a screwdriver to do so Figure 2 8 Step 4 Remove the broken fuse from the selector as shown in Figure 2 9 Figure 2 9 Step 5 Replace with the new fuse as shown in Figure 2 10 Figure 2 10 Step 6 In...

Страница 14: ...plugging as shown in Figure 2 12 Figure 2 12 POWER OFF Step 8 After finishing the above procedures you can plug in your power cord as shown in Figure 2 13 Figure 2 13 Step 9 Press on the power switch...

Страница 15: ...the AC power You must be qualified personnel to perform this action Warning For continued protection against fire or instrument damage only replace fuse with the same type and rating If the instrument...

Страница 16: ...Figure 2 17 Step 3 Pull out the terminal fuse holder gently and you will find the current input fuse as shown in Figure 2 18 Figure 2 18 Step 4 Remove the broken fuse and replace a new one with the sa...

Страница 17: ...urrent Input Fuse Replacement 7A on the rear Panel Verify that the power line fuse is good Replace the fuse if it is damaged Use only the same type and same rating fuse 7A 250V Fast Acting TEXIO part...

Страница 18: ...leasing the holder as shown in Figure 2 22 Figure 2 22 Step 3 Pull out the terminal fuse holder gently and you will find the current input fuse as shown in Figure 2 23 Figure 2 23 Step 4 Remove the br...

Страница 19: ...13 Step 5 Insert the fuse holder back and turn it right as shown in Figure 2 25 Make sure the fuse holder is properly seated and secured Figure 2 25...

Страница 20: ...Current AC Digits 5 1 2 DC Digits Slow 5 1 2 1 PLC Range Auto Frequency and Period Digits 5 1 2 Range Auto Rate Medium 100ms Diode Test Digits 5 1 2 Range 1mA Rate 0 1 PLC Resistance 2 wire Digits Sl...

Страница 21: ...Function Introduction For users to become familiar with the DL 2060 DMM we will give a brief introduction to the basic operations of DL 2060 DMM There are three major parts of DL 2060 1 3 1 the front...

Страница 22: ...AX Captures the minimum or maximum readings from the measurement NULL Activates the offset function in order to get the real measured reading 2 4 Second row with SHIFT button STEP Scans from a channel...

Страница 23: ...r range AUTO Enables or disables auto range 5 Terminals Selects input signal connections on front or rear panel 6 Inserted Connections Fuse Device HI LO Used for all measurements except DC and AC curr...

Страница 24: ...TH Indicates the MATH operation is taken ERR Error occurs SHIFT Indicates SHIFT button is pressed REAR The rear panel input terminal is selected for the measurement FILT The digital filter is started...

Страница 25: ...igger Input Terminal Inputs a low true pulse TTL level from a remote interface 3 USB Connection Connects a remote computer for changing operation environment instead of the front panel control 4 Prote...

Страница 26: ...o the multimeter Applying excess voltage may damage your meter or cause possible electric shock or personal injury Note To eliminate the thermal EMFs due to the differences between two metals use copp...

Страница 27: ...21 Figure 3 1 Figure 3 2 Note The rear panel terminals can also be used via the same procedures as the front panel terminals Refer to Figure 3 3 Figure 3 3 1 2 3 4 6 5 2 1 3 4 5 6...

Страница 28: ...use copper leads to connect your source signal to the meter How to measure current Selects input signal connections on front or rear panel Connect the test leads to the terminals as shown in Figure 3...

Страница 29: ...for low resistance measurements The trade off is the longer settling time for 4 wire mode Figure 3 8 and 3 9 shows the input terminal connections on the rear panel for 2 wire mode and 4 wire mode res...

Страница 30: ...24 Figure 3 6 Figure 3 7 Note The rear terminal panel can also be used via the same procedures like the front panel as shown in Figures 3 8 and 3 9 Figure 3 8 1 2 3 4 6 5 1 3 4 6 2 5...

Страница 31: ...nel Connect the test leads to the terminals as shown in Figure 3 2 Set RESOLUTION Refer to 3 1 1 and INPUT JACK Or skip this step if default is to be used Press FREQ button for frequency measurement o...

Страница 32: ...arning The maximum input voltage allowed is 1000 V peak Applying excess voltage may damage the meter and cause unpredictable hazards How to measure the continuity Selects input signal connections on f...

Страница 33: ...etup for BEEP that can be made within the MENU is OFF How to measure diode Selects input signal connections on front or rear panel Connect the diode to the terminals For forward bias connect the probe...

Страница 34: ...e Range F E 270 to 1000 518 to 1832 J 210 to 1200 140 to 2192 K 270 to 1372 518 to 2502 N 270 to 1300 518 to 2372 R 50 to 1768 122 to 3236 S 50 to 1768 122 to 3236 T 270 to 400 518 to 752 RTD PT 100 2...

Страница 35: ...and measuring procedures in the following sections The source current for the RTD measurement is 1 mA 2 7 2 1 2 Wire RTD Measurements How to measure temperature with 2 Wire RTD The following Figure 3...

Страница 36: ...the reading on the display Note When users do the 3 wire RTD measurement the input LO and sense LO have to be connected in short condition Note Source means RTD Probe Figure 3 15 2 7 2 3 4 Wire RTD M...

Страница 37: ...31 Figure 3 17 1 2 3 5 5 4...

Страница 38: ...Auto Zero Zero The purpose of Auto Zero functions are used for minimizing the offset influence on your measurements When Auto Zero is enabled no individual setup DL 2060 takes the input signal readin...

Страница 39: ...ENU and then ENTER on SET ADC If SET ADC is not shown on the display use and buttons to locate it Press ENTER on ZERO Again use and buttons to locate it if it is not shown on the display Press ENTER o...

Страница 40: ...It also affects the speed of the multimeter to yield a measurement reading Digital filter further stabilizes the measurement readings by averaging Both of them are described in detail in the subsequen...

Страница 41: ...on your selection There are three options 3Hz 20Hz and 200Hz The locations of these buttons are shown with red rectangle frames in Figure 4 2 Figure 4 2 Remote Interface Operation From your PC termin...

Страница 42: ...ault How to enable disable digital filter Press FILTER button to switch the digital filter function The FILT anunnciator indicates the state of the digital filter When it is lit the filter is enabled...

Страница 43: ...resolution setting is stored in a volatile memory and the setting is only valid for the current measurement function Please refer to Table 2 1 on page 14 Note The resolution setting for AC measurement...

Страница 44: ...3 Remote Interface Operation Use the following commands on your PC terminal to set the resolution for your measurement CONFigure function range resolution MEASure function range resolution SENSe funct...

Страница 45: ...CV 1000 V DCV and other measurement functions the input resistance is fixed at 10M and can not be changed Also note that the user selected value is stored in a volatile memory The default setting will...

Страница 46: ...beeper goes off when the measured resistance is less than the threshold resistance The threshold resistance can be set to any value between 1 and 1000 Default The factory default for continuity thresh...

Страница 47: ...user selected range is stored in volatile memory and the default will be restored when the meter is power off Please refer to Table 2 1 on page 14 for the factory default range How to set the auto man...

Страница 48: ...DCV DCI and resistance measurement the default integration time is 1 PLC The user selected value is stored in a volatile memory and the default value will be restored when the meter is power off How...

Страница 49: ...AXimum SENSe PERiod APERture MINimum MAXimum 3 1 8 Sensor Selection for Temperature Measurements The multimeter supports both thermocouple and RTD User needs to configure the multimeter for the right...

Страница 50: ...lements needed and details on RTD calibration refer to NIST Technical Note 1265 Guidelines For Realizing the International Temperature Scale of 1990 In each subrange the calibration constants required...

Страница 51: ...Ximum SENSe TEMPerature SPRTD DX value MINimum MAXimum Thermocouple Definition If users are using the thermocouple function the selections on the DL 2060 are type E J K N R S and T On the other hand o...

Страница 52: ...1 05 or upward 3 1 9 Remote Interface Selection The multimeter supports GP IB G VG type RS 232C R VR type and USB interfaces but only one interface can be activated at a time If you are using GP IB yo...

Страница 53: ...ont panel as well as the rear panel If the rear terminal is enabled the REAR annunciator at the upper side will be shown Default The default situation is the front terminals How to switch the terminal...

Страница 54: ...le status when DL 2060 is not measuring sampling display will illuminates when measurement is in progress When starting measurement after idle status the trigger system should be in trigger waiting st...

Страница 55: ...o the default for trigger mode in DL 2060 How to use Auto Trigger Press ATUO TRIGGER on the front panel to toggle for enabling auto trigger mode The location of the button is shown with a red rectangl...

Страница 56: ...ith a red rectangle frame in Figure 4 10 Figure 4 10 3 2 2 Trigger Source In DL 2060 user can specify the trigger source to be one of these three options front panel operations external hardware trigg...

Страница 57: ...5V TTL L 0V Approximately 2 s Remote Interface Operation By software or internal trigger By software trigger The software trigger is similar to the single triggering but instead of using the SINGLE bu...

Страница 58: ...MENU button and locate TRIG submenu by pressing and buttons Press ENTER to choose TRIG option Again locate N SAMPLE submenu using and buttons and then press ENTER to select it Then set the desired num...

Страница 59: ...simply press AUTO TRIGGER The locations of the buttons are shown with red rectangle frames in Figure 4 12 Figure 4 12 D Trigger delay This feature is useful for user who needs a longer delay time to w...

Страница 60: ...Trigger Single Trigger 3 Hz 7 0 s 20 Hz 1 0 s 200 Hz 600 ms ACV ACI Front Panel w Auto Trigger On 3 Hz 1 5 s 20 Hz 200 ms 200 Hz 100 ms Frequency Period Remote Interface ternal 1 0 s Front Panel Auto...

Страница 61: ...ght math operations RITIO Min Max NULL Limits MX B dB and dBm testing They either store data for later use or perform mathematical operations on the readings Note that these math operations are availa...

Страница 62: ...nals Then connect the SENSE LO to the INPUT LO terminals Front Panel Operation Use TERMINALS button to select the front terminals or the rear terminals For operating this function please press RATIO b...

Страница 63: ...target value user needs to configure Percent function by pressing CONFIG then use and to move through the digits and and buttons to increase or decrease the numbers to a desired target value Press EN...

Страница 64: ...Min Max feature either through the front panel operation or the remote interface operation Front Panel Operation User first selects the measurement function they wish to use and then press MIN MAX but...

Страница 65: ...rom either the front panel operation or the remote interface operation The Front Panel Operation The null measurements can be used with any function except continuity and diode To store the null test...

Страница 66: ...The default values for both upper and lower limits are 0 This function is available to all except continuity and diode measurements How to set the limits You can set the limits or make a limit testing...

Страница 67: ...MATH anunnciator on the display indicates the state of a mathematical feature Figure 4 19 Remote Interface Operation Use the following commands to enable the limits function or to set the limits CALCu...

Страница 68: ...interface reset User can either use front panel or remote interface to perform this function and set these two constant How to use MX B function You can use MX B function from the front panel operati...

Страница 69: ...able and configure MX B function CALCulate FUNCtion MXB CALCulate STATe OFF ON CALCulate STATe CALCulate MXB MMFactor value MINimum MAXimum CALCulate MXB MMFactor MINimum MAXimum CALCulate MXB MBFacto...

Страница 70: ...again to disable this feature The MATH anunnciator on the display indicates the state of a mathematical feature Front Panel Operation Method 1 Manual setup of relative value Press CONFIG SHIFT dB NUL...

Страница 71: ...put voltage ref Z is the reference resistance Note Change of reference resistance will not affect the stored relative reference value The Zref is adjustable with a range from 50 to 8000 The default va...

Страница 72: ...e default for the reference resistance is 600 The locations of the buttons are shown with red rectangle frames in Figure 4 24 Note Press SHIFT dBm MIN MAX again to disable this feature The MATH anunnc...

Страница 73: ...e measurement readings will not be sent to the display This option will accelerate the measurement process because there is no I O delay But turning off the display will not affect the messages displa...

Страница 74: ...2060 multimeter beeps when some certain conditions are met or when an error occurs But there may be time you want to disable the beeper for some operations Although you can turn off the beeper the cl...

Страница 75: ...again use and buttons to find BEEP menu Press ENTER to choose it and then find ON or OFF by using and buttons Press ENTER on your selection The locations of the buttons are shown with red rectangle f...

Страница 76: ...mber of readings to store is 100 To change this number press CONFIG and then STORE buttons Then use and buttons to move between the digits and and buttons to increase or decrease numbers as desired Wh...

Страница 77: ...old decides which reading is stable enough This band is expressed as a percent of reading on the selected range The multimeter considers a reading stable when three consecutive values are within the b...

Страница 78: ...rough all defined channels in sequence The scan count limits the total number of measurements the multimeter makes through all defined channels in one single scanning operation The scan interval is th...

Страница 79: ...channels of 2 pole relay input All channels configurable to 4 pole CAPABILITIES Multiplex one of twenty 2 pole or one of ten 4 pole signals into DMM MODEL OP 41 OP 41T OP 42 Maximum AC Voltage 125V rm...

Страница 80: ...HI LO HI LO HI LO HI LO HI LO Channel 11 Channel 12 Channel 13 Channel 14 Channel 15 Channel 16 Channel 17 Channel 18 Channel 19 Channel 20 Speed of Scanner Card Measurement AutoZero OFF AutoRange OFF...

Страница 81: ...OUNT scan interval TIMER and store STORE options Then press ENTER on your selection Use and to move through the digits and and to increase or decrease the numbers to a desired value For STORE option y...

Страница 82: ...terval and store measurement readings Press CONFIG SHIFT FILTER for scanning configuration Use and buttons to scroll through submenus Press ENTER to select OPERATION submenu Use and to switch among sc...

Страница 83: ...measurement install the cable for OUTPUT on OUTB as well OUTB To DMM Input CH6 CH7 CH8 CH9 CH10 HI LO HI LO HI LO HI LO HI LO LO HI OUTA HI LO HI LO HI LO HI LO HI LO CH1 CH2 CH3 CH4 CH5 LO HI To DMM...

Страница 84: ...the cause of an incorrect measurement if the screw is not tightened into the rear panel Step Please insert the cable for OUT from the scanner card into the rear side input of DL 2060 When measuring 4...

Страница 85: ...rement and Current Shunt resistor Accurately measure the resistance value of the Current Shunt resistor then setup R and I R shunt resistance value I Offset The measurement function of each channel wi...

Страница 86: ...e Types Units Simulated 5 Step Scan Count Timer 6 dBm Reference Resistance 7 MX B Values M B 8 Reading Hold Sensitivity Band 9 Input R DC Input Resistance 10 Interface USB GPIB ADDR 11 System Language...

Страница 87: ...e front panel display tells about the error condition of the multimeter If there are one or more syntax or hardware errors found the error annunciator will be lit to inform user The multimeter stores...

Страница 88: ...ware Revision DL 2060 has three microprocessors for various internal systems You can query the multimeter to determine which revision of firmware is installed for each microprocessor How to check the...

Страница 89: ...Figure 4 36 3 4 13 Calibration Notice Do not use CAL MENU since it is aimed for maker calibration 3 4 14 Self test Notice Do not use SELF TEST since it is used only for an after sales service operati...

Страница 90: ...the internal pass and fail TTL output signals limit testing will be connected to the USB connector The pass and fail signals are low true and indicate the Math Pass Fail Limit Test result for the next...

Страница 91: ...n Next following software should be installed into the PC for control Following to NI VISA3 1 DL Driver Also application software for control is prepared into the attached CD besides of above software...

Страница 92: ...CURRent AC range MIN MAX DEF resolution MIN MAX DEF RESistance range MIN MAX DEF resolution MIN MAX DEF FRESistance range MIN MAX DEF resolution MIN MAX DEF FREQuency range MIN MAX DEF resolution MIN...

Страница 93: ...internal memory when using the READ Command Using the READ Command has a similar effect as using the INITiate command followed immediately by the FETCh command except readings are not buffered intern...

Страница 94: ...e range MINimum MAXimum VOLTage AC RANGe MINimum MAXimum CURRent DC RANGe range MINimum MAXimum CURRent DC RANGe MINimum MAXimum CURRent AC RANGe range MINimum MAXimum CURRent AC RANGe MINimum MAXimum...

Страница 95: ...CURRent DC RESolution resolution MINimum MAXimum CURRent DC RESolution MINimum MAXimum CURRent AC RESolution resolution MINimum MAXimum CURRent AC RESolutioin MINimum MAXimum RESistance RESolution res...

Страница 96: ...lue MINimum MAXimum TEMPerature SPRTD A4 MINimum MAXimum TEMPerature SPRTD B4 value MINimum MAXimum TEMPerature SPRTD B4 MINimum MAXimum TEMPerature SPRTD AX value MINimum MAXimum TEMPerature SPRTD AX...

Страница 97: ...BANDwidth 3 20 200 MINimum MAXimum DETector BANDwidth MINimum MAXimum SENSe AVERage TCONtrol MOVing REPeat AVERage TCONtrol AVERage COUNt value MINimum MAXimum AVERage COUNt MINimum MAXimum AVERage S...

Страница 98: ...ing The math operations use one or more internal registers You can preset the values in some of the registers while others hold the results of the math operations CALCulate FUNCtion PERCent AVERage NU...

Страница 99: ...onfigure the mulitmeter by choosing the desired function range and resolution Specify the trigger source from which the multimeter will accept the trigger The multimeter takes immediate internal trigg...

Страница 100: ...NFinite COUNt MINmum MAXimum SYSTEM RELATED Commands Each system related operation performs a task that is not measurement related but plays an important role in making your measurements FETCh READ DI...

Страница 101: ...1 STATUS REPORTING Commands SYSTem ERRor STATus QUEStionable ENABle enable value QUEStionable ENABle QUEStionable EVENt STATus PRESet CLS ESE enable value ESE ESR OPC OPC PSC 0 1 PSC SRE enable value...

Страница 102: ...96 Other Interface Commands SYSTem LOCal SYSTem REMote GPIB IEEE 488 2 COMMON Commands CLS ESE enable value ESE ESR IDN OPC OPC PSC 0 1 PSC RST SRE enable value SRE STB TRG...

Страница 103: ...h 0 No error The error queue is cleared when power has been off or after a CLS clear status command has been executed The RST reset command does not clear the error queue 5 1 Error Type There is only...

Страница 104: ...arger than 32000 was found 124 Too many digits A numeric parameter was found whose mantissa contained more than 255 digits excluding leading zeros 131 Invalid suffix A suffix was incorrectly specified...

Страница 105: ...ted in one of the following situations Situation 1 You sent a CONFigure or MEASure command with autorange enabled and with a fixed resolution Situation 2 You turned math on and then changed to a math...

Страница 106: ...522 Output buffer overflow 531 Insufficient memory There is not enough memory to store the requested number of readings in internal memory using the INITiate command The product of the sample count SA...

Страница 107: ...0045 0 0006 1000 000 V 1 mV 10 M 0 0045 0 0010 Function Range Resolution Shunt Resistance 1 Year 23 5 DC Current 10 00000mA 10 nA 5 1 0 050 0 020 100 0000mA 100 nA 5 1 0 050 0 005 1 000000A 1 A 0 1 0...

Страница 108: ...000000 M 1 5 A 0 010 0 001 10 00000 M 10 500 nA 0 040 0 001 100 0000 M 100 500 nA 10 M 0 800 0 010 Diode Test 1 0000 V 10 V 1 mA 0 010 0 020 Continuity 1000 00 10 m 1 mA 0 010 0 030 a Specifications...

Страница 109: ...8 100 k 300 k 4 00 0 50 1 000000 V to 750 000 V 1 0 V to 1 mV 3 5 1 00 0 03 5 10 0 35 0 03 10 20 k 0 06 0 03 20 k 50 k 0 12 0 05 50 k 100 k 0 60 0 08 100 k 300 k 4 00 0 50 AC Current TRMS 1 000000 A 1...

Страница 110: ...age Temperature 10 to 60 Operating Altitude Up to 2000m Bench Dimensions WxHxD 224 mm x 113 mm x 373 mm Weight Approx 4 4 kg Safety EN61010 1 2010 3rd Edition conformity EMC EN61326 1 2013 conformity...

Страница 111: ...n below to illustrate the tree system SENSe VOLTage DC RANGe range MINimum MAXimum VOLTage DC RANGe MINimum MAXimum FREQuency VOLTage RANGe range MINimum MAXimum FREQuency VOLTage RANGe MINimum MAXimu...

Страница 112: ...ts The brackets are not sent with the command string You must specify a value for the parameter such as VOLT DC RANG 10 Some parameters are enclosed in square brackets The brackets indicate that the p...

Страница 113: ...ines a set of common commands that perform functions like reset self test and status operations Common commands always begin with an asterisk are four to five characters in length and may include one...

Страница 114: ...condition that is either true or false For a false condition the multimeter will accept OFF or 0 For a true condition the multimeter will accept ON or 1 When you query a boolean setting the instrument...

Страница 115: ...tput buffer MEASure VOLTage DC RATio range MIN MAX DEF resolution MIN MAX DEF Preset and make a dc dc ratio measurement with the specified range and resolution The reading is sent to the output buffer...

Страница 116: ...y measurements the meter uses only one range for all inputs between 3Hz and 300kHz With no input signal applied frequency measurements return 0 MEASure PERiod range MIN MAX DEF resolution MIN MAX DEF...

Страница 117: ...rements with the specified range and resolution This command does not initiate the measurement CONFigure CURRent AC range MIN MAX DEF resolution MIN MAX DEF Preset and configure the multimeter for AC...

Страница 118: ...measurement The range and resolution are fixed at 1k and 5 digits respectively CONFigure DIODe Preset and configure for a diode measurement This command does not initiate the measurement The range an...

Страница 119: ...MAX selects the highest range SENSe function RANGe MINimum MAXimum Query the range for the selected function For frequency and period use FREQuency VOLTage or PERiod VOLTage Autorange thresholds Down...

Страница 120: ...nce junction type SENSe TCOuple RJUNction REAL Query a current temperature of the reference junction SENSe TCOuple RJUNction SIMulated value MINimum MAXimum Set the SIMulated value for Thermocouple fu...

Страница 121: ...MINimum MAXimum Query the beta constant for the user type SENSe TEMPerature RTD DELTa value MINimum MAXimum Set the delta constant for the user type SENSe TEMPerature RTD DELTa MINimum MAXimum Query t...

Страница 122: ...SPRTD DX value MINimum MAXimum Set the D coefficient SENSe TEMPerature SPRTD DX MINimum MAXimum Query the D coefficient SENSe TEMPerature TRANsducer FRTD Set the RTD Measurement to 4 Wire SENSe TEMPe...

Страница 123: ...Ximum Query the gate time or aperture time for period function SENSe DETector BANDwidth 3 20 200 MINimum MAXimum Specify the lowest frequency expected in the input signal The meter selects the slow me...

Страница 124: ...AN FUNCtion channel function VOLT DC VOLT AC FREQuency RESistance FRESistance PERiod TCOuple TEMPerature NONE Set scanner card s measurement functions which might be for the VAC VDC Frequency 2 Wire R...

Страница 125: ...e value when Min Max is turned on when the power has been off or a remote interface reset CALCulate PERCent TARGet MINimum MAXimum Query the target value for percent math function CALCulate AVERage MI...

Страница 126: ...highest range for the present function CALCulate LIMit LOWer Query the lower limit for the limit testing CALCulate LIMit UPPer value MINimum MAXimum Set the upper limit for limit testing You can set...

Страница 127: ...lues An error will be generated if you attempt to transfer readings to the output buffer using the FETCh command DATA FEED Query the reading memory state Return CALC or B 7 The Triggering Commands INI...

Страница 128: ...Gger DELay AUTO Query the automatic trigger delay mode Returns 0 OFF or 1 ON SAMPle COUNt value MINimum MAXimum Set the number of readings samples the multimeter takes per trigger Select a number from...

Страница 129: ...display setting Returns 0 OFF or 1 ON DISPlay TEXT quoted string Show a message on the front panel display The allowed message can be up to 16 characters in the lower row display any additional charac...

Страница 130: ...All buttons on the front panel are fully functional SYSTem REMote Place the multimeter in the remote mode All buttons on the front panel except the LOCAL button are disabled B 9 Status Reporting Comma...

Страница 131: ...ed sum of all bits set in the register ESR Query the Standard event register The multimeter returns a decimal value which corresponds to the binary weighted sum of all bits set in the register OPC Set...

Страница 132: ...f the SCPI standard these commands are designed with the SCPI format in mind and they follow all of the syntax rules of the standard Many of the required SCPI commands are accepted by the multimeter b...

Страница 133: ...um MAXimum LIMit LOWer MINimum MAXimum LIMit UPPer value MINimum MAXimum LIMit UPPer MINimum MAXimum MXB MMFactor value MINimum MAXimum MXB MMFactor MINimum MAXimum MXB MBFactor value MINimum MAXimum...

Страница 134: ...ferent programming languages and GPIB interface cards provide access to this capability through their own unique commands The status registers the error queue and all configuration states are left unc...

Страница 135: ...129 C Tree Diagram Please refer to G Notice of Scanner Card if your firmware version is 1 05 or upward...

Страница 136: ...130...

Страница 137: ...131...

Страница 138: ...132 D DL 2060 s Dimension...

Страница 139: ...nts However MEASure does not offer much flexibility LISTING E 1 Set the startup object for a Windows application to Sub Main Add a Reference to the VISA Library The sample application requires the fol...

Страница 140: ...t viClose fList Exit Sub End If Rem send measure command Set to 0 1 volt dc range stat viWrite sesn meas volt DC 0 1 0 01 22 ret If stat VI_SUCCESS Then MsgBox System command error meas volt dc vbExcl...

Страница 141: ...fltRM As ViSession Dim sesn As ViSession Dim fList As ViFindList Dim desc As String VI_FIND_BUFLEN Dim nList As Long Dim ret As Long Dim readin As String 128 Dim i As Integer Array index stat viOpenDe...

Страница 142: ...r stat viWrite sesn DET BAND 200 12 ret If stat VI_SUCCESS Then MsgBox System command error vbExclamation DL 2060 multimeter device test stat viClose fList Exit Sub End If Rem send command kDL 2060 wi...

Страница 143: ...ta error vbExclamation DL 2060 multimeter device test stat viClose fList Exit Sub End If Rem set to local mode stat viWrite sesn system local 12 ret If stat VI_SUCCESS Then MsgBox System command error...

Страница 144: ...l include stdafx h include visa h standard include for a Microsoft Visual C project include stdio h include windows h void main int argc char argv TODO Add your control notification handler code here...

Страница 145: ...e PviRead_usb signed long __stdcall unsigned long unsigned char unsigned long unsigned long GetProcAddress hUSBTMCLIB LPCSTR viRead PviSetAttribute_usb signed long __stdcall unsigned long unsigned lon...

Страница 146: ...str_usbtmc unsigned char pStrout 6 nWritten Sleep 30 if status VI_SUCCESS MessageBox NULL Write to device error DL 2060 multimeter device test MB_OK PviClose_usb m_defaultRM_usbtmc hUSBTMCLIB NULL m_d...

Страница 147: ...viWrite_usb m_instr_usbtmc unsigned char pStrout 21 nWritten Sleep 1000 Send read command strcpy pStrout READ status PviWrite_usb m_instr_usbtmc unsigned char pStrout 6 nWritten Sleep 30 printf output...

Страница 148: ...100 00 V 1 000000E 02 0 01 2 000000E 02 0 0 2 100 0 01 SLOW 4 1 2 digits 100 00 V 1 000000E 03 0 001 1 000000E 01 0 1 FAST 5 1 2 digits 100 000 V 1 000000E 03 0 001 1 000000E 01 0 1 100 0 001 SLOW 5...

Страница 149: ...digits 100 0000 M 1 000000E 0 2 100 1 000000E 0 0 1 100000000 100 SLOW 6 1 2 digits 100 0000 M 1 000000E 0 1 10 1 000000E 0 1 10 10000000 10 SENS CURR DC RES resolution DCA MEAS CURR DC range resolut...

Страница 150: ...gits 3 0000 Hz 1 000000E 02 0 01 FREQ 3 000000E 00 3 000000E 04 3 0 0003 0 00001 SLOW 5 1 2 digits 3 00000 Hz 1 000000E 01 0 1 FREQ 3 000000E 00 3 000000E 05 3 0 00003 0 00001 SLOW 6 1 2 digits 3 0000...

Страница 151: ...NTCT scanner channel number SENSe TEMPerature RTD TYPE scanner channel number SENSe TEMPerature TRANsducer FRTD scanner channel number SENSe TEMPerature TRANsducer RTD scanner channel number SENSe TEM...

Страница 152: ...7F Towa Fudosan Shin Yokohama Bild 2 18 13 Shin Yokohama Kohoku ku Yokohama Kanagawa 222 0033 Japan http www texio co jp...

Отзывы: