SERDES Register Map
471
SBAU337 – May 2020
Copyright © 2020, Texas Instruments Incorporated
Serial Interface Register Maps
Table 2-732. Register 4010 Field Descriptions
Bit
Field
Type
Reset
Description
7-7
DFE_INIT_2[0]
R/W
0h
The initialization value2 for DFE in in S7.6 format
6-0
DFE_INIT_3
R/W
8h
The initialization value3 for DFE in in S7.6 format
2.6.13 Register 4011h (offset = 4011h) [reset = 20h]
Figure 2-727. Register 4011h
7
6
5
4
3
2
1
0
DFE_INIT_2[6:1]
R/W-20h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-733. Register 4011 Field Descriptions
Bit
Field
Type
Reset
Description
5-0
DFE_INIT_2[6:1]
R/W
20h
The initialization value2 for DFE in in S7.6 format
2.6.14 Register 4012h (offset = 4012h) [reset = 18h]
Figure 2-728. Register 4012h
7
6
5
4
3
2
1
0
DFE_INIT_4
R/W-18h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-734. Register 4012 Field Descriptions
Bit
Field
Type
Reset
Description
6-0
DFE_INIT_4
R/W
18h
The initialization value4 for DFE in value in S7.6 format
2.6.15 Register 4015h (offset = 4015h) [reset = 40h]
Figure 2-729. Register 4015h
7
6
5
4
3
2
1
0
MU_MARGIN
R/W-1h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-735. Register 4015 Field Descriptions
Bit
Field
Type
Reset
Description
7-6
MU_MARGIN
R/W
1h
Controls DFE loop's MU adaptation rate.
2.6.16 Register 4016h (offset = 4016h) [reset = 15h]
Figure 2-730. Register 4016h
7
6
5
4
3
2
1
0
HF_CNTR_THRESH
R/W-15h