RX Top Register Map
750
SBAU337 – May 2020
Copyright © 2020, Texas Instruments Incorporated
Serial Interface Register Maps
2.13.129 Register 47Ah (offset = 47Ah) [reset = 8h]
Figure 2-1541. Register 47Ah
7
6
5
4
3
2
1
0
RX_AGC_BAND1_DECAY_NUM_HITS[23:16]
R/W-8h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1554. Register 47A Field Descriptions
Bit
Field
Type
Reset
Description
7-0
RX_AGC_BAND1_
DECAY_NUM_HIT
S[23:16]
R/W
8h
Number of Hits threshold digital band1 detector in decay
mode.
2.13.130 Register 484h (offset = 484h) [reset = 0h]
Figure 2-1542. Register 484h
7
6
5
4
3
2
1
0
RX_AGC_BAND0_PEAK_DET_DECAY_WIN_LEN[7:0]
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1555. Register 484 Field Descriptions
Bit
Field
Type
Reset
Description
7-0
RX_AGC_BAND0_
PEAK_DET_DECA
Y_WIN_LEN[7:0]
R/W
0h
Band0 peak detector window length in decay mode. When
decay detectors are in sync mode this window length is used
by all decay detectors. Max supported length is 2^24 - 2.
Window length is defined in terms of band detector tap-off
point clock rate.
2.13.131 Register 485h (offset = 485h) [reset = 80h]
Figure 2-1543. Register 485h
7
6
5
4
3
2
1
0
RX_AGC_BAND0_PEAK_DET_DECAY_WIN_LEN[15:8]
R/W-80h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1556. Register 485 Field Descriptions
Bit
Field
Type
Reset
Description
7-0
RX_AGC_BAND0_
PEAK_DET_DECA
Y_WIN_LEN[15:8]
R/W
80h
Band0 peak detector window length in decay mode. When
decay detectors are in sync mode this window length is used
by all decay detectors. Max supported length is 2^24 - 2.
Window length is defined in terms of band detector tap-off
point clock rate.