RX Top Register Map
751
SBAU337 – May 2020
Copyright © 2020, Texas Instruments Incorporated
Serial Interface Register Maps
2.13.132 Register 486h (offset = 486h) [reset = 0h]
Figure 2-1544. Register 486h
7
6
5
4
3
2
1
0
RX_AGC_BAND0_PEAK_DET_DECAY_WIN_LEN[23:16]
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1557. Register 486 Field Descriptions
Bit
Field
Type
Reset
Description
7-0
RX_AGC_BAND0_
PEAK_DET_DECA
Y_WIN_LEN[23:16]
R/W
0h
Band0 peak detector window length in decay mode. When
decay detectors are in sync mode this window length is used
by all decay detectors. Max supported length is 2^24 - 2.
Window length is defined in terms of band detector tap-off
point clock rate.
2.13.133 Register 489h (offset = 489h) [reset = Fh]
Figure 2-1545. Register 489h
7
6
5
4
3
2
1
0
RX_AGC_BAND0_PWR_DET_DECAY_WIN_LEN
R/W-Fh
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1558. Register 489 Field Descriptions
Bit
Field
Type
Reset
Description
4-0
RX_AGC_BAND0_
PWR_DET_DECA
Y_WIN_LEN
R/W
Fh
Power detector decay window length for Band 0. Actual
window length used is 2 power programmed value. Supported
length is only upto 2^23. Window length is defined in terms of
band detector tap-off point clock rate.
2.13.134 Register 48Dh (offset = 48Dh) [reset = Fh]
Figure 2-1546. Register 48Dh
7
6
5
4
3
2
1
0
RX_AGC_BAND1_PWR_DET_DECAY_WIN_LEN
R/W-Fh
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1559. Register 48D Field Descriptions
Bit
Field
Type
Reset
Description
4-0
RX_AGC_BAND1_
PWR_DET_DECA
Y_WIN_LEN
R/W
Fh
Power detector decay window length for Band 1. Actual
window length used is 2 power programmed value. Supported
length is only upto 2^23. Supported length is only upto 2^23.
Window length is defined in terms of band detector tap-off