SERDES Register Map
468
SBAU337 – May 2020
Copyright © 2020, Texas Instruments Incorporated
Serial Interface Register Maps
2.6.2 Register 4001h (offset = 4001h) [reset = 10h]
Figure 2-716. Register 4001h
7
6
5
4
3
2
1
0
LANE_RESET
DFE_INIT_1
R/W-0h
R/W-10h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-722. Register 4001 Field Descriptions
Bit
Field
Type
Reset
Description
7-7
LANE_RESET
R/W
0h
State machine reset level trigger
1h Reset
6-0
DFE_INIT_1
R/W
10h
The initialization value1 for DFE in S7.6 format
2.6.3 Register 4002h (offset = 4002h) [reset = 8h]
Figure 2-717. Register 4002h
7
6
5
4
3
2
1
0
CNTR_TARGET_DEPTH[7:0]
R/W-8h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-723. Register 4002 Field Descriptions
Bit
Field
Type
Reset
Description
7-0
CNTR_TARGET_D
EPTH[7:0]
R/W
8h
The smaller this value, the deeper the eye target.
2.6.4 Register 4003h (offset = 4003h) [reset = 0h]
Figure 2-718. Register 4003h
7
6
5
4
3
2
1
0
CNTR_TARGET_DEPTH[11:8]
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-724. Register 4003 Field Descriptions
Bit
Field
Type
Reset
Description
3-0
CNTR_TARGET_D
EPTH[11:8]
R/W
0h
The smaller this value, the deeper the eye target.
2.6.5 Register 4004h (offset = 4004h) [reset = 20h]
Figure 2-719. Register 4004h
7
6
5
4
3
2
1
0
CNTR_TARGET_PAT[7:0]
R/W-20h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset