List of Macros
127
SBAU337 – May 2020
Copyright © 2020, Texas Instruments Incorporated
Macro
Table 1-75. (continued)
Macro
AGC State Control
2
0x01
2
AGC State Register.
This is a 11-bit
register with each
bit having the
functionality as
mentioned below:
(Bit 0 corresponds
to the LSB bit)
Bit 0: 1
→
Start
AGC with entire
configuration
redone
Bit 1: 1
→
Freeze
the AGC loop
Bit 2 : 1
→
Unfreeze
the AGC loop (takes
effect only if the
loop is already in
freeze)
Bit 3: 1
→
Reset the
AGC loop
Bit 4: 1
→
ALC
Block enable
Bit 5: 1
→
ALC
Block disable
Bit 6: 1
→
External
AGC enable
Bit 7: 1
→
External
AGC disable
Bit 8: 1
→
Toggle
the AGC enable
Bit 9: 1
→
Toggle
the ALC enable
Bit 10: 1
→
Toggle
the external AGC
enable
Memory
Not used
1.2.5.16.1 Error Reporting
Table 1-76.
Error Status Registers
Interpretation
Error Status 1 (16-bit)
0
→
INVALID_AGC_EN_COMBINATION (AGC start/rese/toggle
can be done only one at a time)
1
→
INVALID_(ALC/EXT_AGC)_EN_COMBINATION (ALC
start/rese/toggle can be done only one at a time or External
AGC start/reset/toggle can be done only one at a time)
3
→
INVALID_AGC_FREEZE_COMBINATION(AGC freeze and
unfreeze cannot be done at the same time)
4
→
INVALID_INT_AND_EXT_AGC_COMBINATION
Error Code 2 (32-bit)
Not Used
1.2.5.17 ALC Configuration Macro
Table 1-77.
Macro
ALC Configuration
Opcode
0x69
Operand
Offset
Length
Value
Functionality
Results