RX Top Register Map
747
SBAU337 – May 2020
Copyright © 2020, Texas Instruments Incorporated
Serial Interface Register Maps
Table 2-1543. Register 45D Field Descriptions
Bit
Field
Type
Reset
Description
7-0
RX_AGC_SMALL_
STEP_DECAY_NU
M_HITS[15:8]
R/W
0h
Number of Hits threshold for digital small step decay detector.
2.13.119 Register 45Eh (offset = 45Eh) [reset = 8h]
Figure 2-1531. Register 45Eh
7
6
5
4
3
2
1
0
RX_AGC_SMALL_STEP_DECAY_NUM_HITS[23:16]
R/W-8h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1544. Register 45E Field Descriptions
Bit
Field
Type
Reset
Description
7-0
RX_AGC_SMALL_
STEP_DECAY_NU
M_HITS[23:16]
R/W
8h
Number of Hits threshold for digital small step decay detector.
2.13.120 Register 460h (offset = 460h) [reset = 0h]
Figure 2-1532. Register 460h
7
6
5
4
3
2
1
0
RX_AGC_LNA_RF_DET_ATTACK_NUM_HITS[7:0]
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1545. Register 460 Field Descriptions
Bit
Field
Type
Reset
Description
7-0
RX_AGC_LNA_RF
_DET_ATTACK_N
UM_HITS[7:0]
R/W
0h
LNA RF attack det threshold. If Number of hits is greater than
this, detector is triggered. Note that per clock we may get up
to 8 hits.
2.13.121 Register 461h (offset = 461h) [reset = 0h]
Figure 2-1533. Register 461h
7
6
5
4
3
2
1
0
RX_AGC_LNA_RF_DET_ATTACK_NUM_HITS[15:8]
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1546. Register 461 Field Descriptions
Bit
Field
Type
Reset
Description
7-0
RX_AGC_LNA_RF
_DET_ATTACK_N
UM_HITS[15:8]
R/W
0h
LNA RF attack det threshold. If Number of hits is greater than
this, detector is triggered. Note that per clock we may get up