MAINTENANCE
87
8210D 330210 (12--00)
The vacuum fan air intake screen should be
checked daily and cleaned as necessary. To clean
the screen, remove it and spray it off with a hose.
DO NOT allow any water to enter the vacuum fan
air intake tube.
SOLUTION TANK
The solution tank contains the cleaning solution.
The solution tank does not require regular
maintenance. If deposits form on the bottom of
the tank, rinse the tank with a strong blast of
warm water. The tank can be flushed through the
drain opening. Drain the tank with the solution
tank drain hose.
The solution tank on machines with the ES option
should be drained and cleaned daily. Rinse the
solution outlet filters at the bottom of the tank
through the drain access.
SQUEEGEES
The rear squeegee channels water into the
vacuum fan suction. The front blade channels the
water, and the rear blade wipes the floor.
The side squeegees control water spray and
channel water into the path of the rear squeegee.
REAR SQUEEGEE
Check the squeegee blades for damage and wear
daily. Rotate or replace either of the squeegee
blades if the leading edge is torn or worn half-way
through the thickness of the blade.
The squeegee can be adjusted for leveling and
deflection. The deflection of the squeegee blades
should be checked daily, or when scrubbing a
different type of floor. The leveling of the
squeegee should be checked every 100 hours of
machine operation.