Model 200E Instruction Manual
Optional Hardware and Software
5. OPTIONAL HARDWARE AND SOFTWARE
This section includes a descriptions of the hardware and software options available for the
Model 200E Nitrogen Oxides Analyzer. For assistance with ordering these options please
contact the sales department of Teledyne - Advanced Pollution Instruments at:
TOLL-FREE:
800-324-5190
TEL:
+1 858-657-9800
FAX:
+1 858-657-9816
E-MAIL:
WEB SITE:
5.1. External Pumps (Option 10)
The M200E comes equipped with an external pump specified upon ordering. Whereas the
analyzer can be re-configured for other voltages, operation at other than the original
voltage/frequency may require a different external pump. A variety of external pumps are
available for the M200E series analyzers. The range of available pump options meets all
typical AC power supply standards while exhibiting the same pneumatic performance.
T-API Part No.
Description
009810300
External pump for 115 VAC / 60 Hz power supply
009810400
External pump for 230 VAC / 50 Hz power supply
009810500
External pump for 110 VAC / 50 Hz power supply
009810600
External pump for 100 VAC / 50 Hz power supply
009810700
External pump for 220-240 VAC / 50-60 Hz power supply
5.2. Rack Mount Kits (Options 20-23)
There are several options for mounting the analyzer in standard 19” racks.
Option Number
Description
OPT 20A
Rack mount brackets with 26 in. chassis slides.
OPT 20B
Rack mount brackets with 24 in. chassis slides.
OPT 21
Rack mount brackets only
OPT 23
Rack mount for external pump (no slides).
5.3. Current Loop Analog Outputs (Option 41)
This option adds isolated, voltage-to-current conversion circuitry to the analyzer’s analog
outputs. This option may be ordered separately for the first three of the analog outputs and
can be installed at the factory or added later. Call T-API sales for pricing and availability.
The current loop option can be configured for any output range between 0 and 20 mA (for
example 0-20, 2-20 or 4-20 mA). Information on calibrating or adjusting these outputs can
be found in Section 6.7.6.
044100102 Rev A
33
Содержание 200E
Страница 15: ...M200E Documentation Model 200E Instruction Manual USER NOTES xiv 044100102 Rev A ...
Страница 19: ...M200E Documentation Model 200E Instruction Manual USER NOTES 4 044100102 Rev A ...
Страница 47: ...Frequently Asked Questions Glossary Model 200E Instruction Manual USER NOTES 32 044100102 Rev A ...
Страница 141: ...Calibration Procedures Model 200E Instruction Manual USER NOTES 126 044100102 Rev A ...
Страница 203: ...Theory of Operation Model 200E Instruction Manual USER NOTES 188 044100102 Rev A ...
Страница 239: ...Troubleshooting Repair Model 200E Instruction Manual USER NOTES 224 044100102 Rev A ...
Страница 243: ...APPENDIX A Model 200E Instruction Manual Figure A 3 Primary Setup Menu Except iDAS 228 044100110 Rev A ...
Страница 244: ...Model 200E Instruction Manual APPENDIX A Figure A 4 Secondary Setup Menu COMM VARS 044100110 Rev A 229 ...
Страница 245: ...APPENDIX A Model 200E Instruction Manual Figure A 5 Secondary Setup Menu DIAG 230 044100110 Rev A ...
Страница 246: ...Model 200E Instruction Manual APPENDIX A Figure A 6 Internal Data Acquisition iDAS Menu 044100110 Rev A 231 ...
Страница 265: ...APPENDIX A Model 200E Instruction Manual USER NOTES 250 044100110 Rev A ...
Страница 271: ...APPENDIX B Model 200E Instruction Manual USER NOTES 256 044100120 Rev A ...
Страница 275: ...APPENDIX D Model 200E Instruction Manual 260 044100141 Rev A USER NOTES ...