76
Functional Description
Load Default Values Into Set [243]
With this function three different levels (factory set-
tings) can be selected for the four parameter sets.
When loading the default settings, all changes made in
the software are set to factory settings. This function
also includes selections for loading default settings to
the four different Motor Data Sets.
Communication information
Copy All Settings to Control Panel [244]
All the settings can be copied into the control panel
including the motor data. Start commands will be
ignored during copying.
Communication information
Load Settings from Control Panel [245]
This function can load all four parameter sets from the
control panel to the VSD. Parameter sets from the
source VSD are copied to all parameter sets in the tar-
get VSD, i.e. A to A, B to B, C to C and D to D.
Start commands will be ignored during loading.
Default:
A
A
0
Only the selected parameter set will revert
to its default settings.
B
1
C
2
D
3
ABCD
4
All four parameter sets will revert to the
default settings.
Factory
5
All settings, except [211], [221]-[22D],
[261], [3A1] and [923], will revert to the
default settings.
M1
6
Only the selected motor set will revert to its
default settings.
M2
7
M3
8
M4
9
M1234
10
All four motor sets will revert to default set-
tnings.
Modbus Instance no/DeviceNet no:
43023
Profibus slot/index
168/182
Fieldbus format
UInt
Modbus format
UInt
NOTE: Trip log hour counter and other VIEW ONLY menus
are not regarded as settings and will be unaffected.
NOTE: If “Factory” is selected, the message “Sure?” is
displayed. Press the + key to display “Yes” and then
Enter to confirm.
NOTE: The parameters in menu [220], Motor data, are
not affected by loading defaults when restoring
parameter sets A–D.
Stp
A
A
Default:
No Copy
No Copy
0
Nothing will be copied
Copy
1
Copy all settings
Modbus Instance no/DeviceNet no:
43024
Profibus slot/index
168/183
Fieldbus format
UInt
Modbus format
UInt
NOTE: The actual value of menu [310] will not be copied
into control panel memory set.
Default:
No Copy
No Copy
0
Nothing will be loaded.
A
1
Data from parameter set A is loaded.
B
2
Data from parameter set B is loaded.
C
3
Data from parameter set C is loaded.
D
4
Data from parameter set D is loaded.
ABCD
5
Data from parameter sets A, B, C and D are
loaded.
A+Mot
6
Parameter set A and Motor data are
loaded.
B+Mot
7
Parameter set B and Motor data are
loaded.
C+Mot
8
Parameter set C and Motor data are
loaded.
D+Mot
9
Parameter set D and Motor data are
loaded.
ABCD+Mot 10
Parameter sets A, B, C, D and Motor data
are loaded.
Stp
No Copy
A
Stp
No Copy
A
Содержание F33 Series
Страница 1: ...TECO F33 Variable Speed Drive Instruction manual English Software version 4 2X...
Страница 3: ......
Страница 33: ...30 Getting Started...
Страница 51: ...48 Main Features...
Страница 53: ...50 EMC and Machine Directive...
Страница 59: ...56 Operation via the Control Panel...
Страница 65: ...62 Serial communication...
Страница 159: ...156 Troubleshooting Diagnoses and Maintenance...
Страница 165: ...162 Options...
Страница 179: ...176 Technical Data...
Страница 187: ...184 Menu List...