
10
Mounting
Fig. 5
Lifting VSD model -0300 to -1500
2.2
Stand-alone units
The VSD must be mounted in a vertical position against
a flat surface. Use the template (delivered together with
the VSD) to mark out the position of the fixing holes.
Fig. 6
Variable speed drive mounting models 0003 to 1500
2.2.1 Cooling
Fig. 6 shows the minimum free space required around
the VSD for the models 0003 to 1500 in order to guar-
antee adequate cooling. Because the fans blow the air
from the bottom to the top it is advisable not to position
an air inlet immediately above an air outlet.
The following minimum separation between two varia-
ble speed drives, or a VSD and a non-dissipating wall
must be maintained. Valid if free space on opposite
side.
Table 4
Mounting and cooling
0003-
0018
0026-
0046
0090-
0250
0300-
1500
cabinet
F33-F33
(mm)
a
200
200 200
100
b
200
200 200
0
c
0
0
0
0
d
0
0
0
0
F33-wall,
wall-one
side
(mm)
a
100
100 100
100
b
100
100 100
0
c
0
0
0
0
d
0
0
0
0
NOTE: When a 0300 to 1500 model is placed between
two walls, a minimum distance at each side of 200 mm
must be maintained.
Содержание F33 Series
Страница 1: ...TECO F33 Variable Speed Drive Instruction manual English Software version 4 2X...
Страница 3: ......
Страница 33: ...30 Getting Started...
Страница 51: ...48 Main Features...
Страница 53: ...50 EMC and Machine Directive...
Страница 59: ...56 Operation via the Control Panel...
Страница 65: ...62 Serial communication...
Страница 159: ...156 Troubleshooting Diagnoses and Maintenance...
Страница 165: ...162 Options...
Страница 179: ...176 Technical Data...
Страница 187: ...184 Menu List...