66
Functional Description
also be activated via a digital input. If
both [2171] and
[2172] is set to Standard, the function is disabled.
Communication information
Communication information
To prevent the keyboard being used or to change the
setup of the VSD and/or process control, the keyboard
can be locked with a password. This menu, Lock Code
[218], is used to lock and unlock the keyboard. Enter
the password “291” to lock/unlock the keyboard opera-
tion. If the keyboard is not locked (default) the selection
“Lock Code?” will appear. If the keyboard is already
locked, the selection “Unlock Code?” will appear.
When the keyboard is locked, parameters can be
viewed but not changed. The reference value can be
changed and the VSD can be started, stopped and
reversed if these functions are set to be controlled from
the keyboard.
Rotation [219]
Overall limitation of motor rotation direction
This function limits the overall rotation, either to left or
right or both directions. This limit is prior to all other
selections, e.g.: if the rotation is limited to right, a Run-
Left command will be ignored. To define left and right
rotation we assume that the motor is connected U-U, V-
V and W-W.
Speed Direction and Rotation
The speed direction can be controlled by:
• RunR/RunL commands on the control panel.
• RunR/RunL commands on the terminal strip
(terminals 1-22).
• Via the serial interface options.
•
The parameter sets.
Fig. 70 Rotation
In this menu you set the general rotation for the motor.
Default:
Standard
Standard
0
Local reference control set via [214]
Remote
1
Local reference control via remote
Keyboard
2
Local reference control via keyboard
Com
3
Local reference control via communication
Modbus Instance no/DeviceNet no:
43009
Profibus slot/index
168/168
Fieldbus format
UInt
Modbus format
UInt
Default:
Standard
Standard
0
Local Run/Stop control set via [215]
Remote
1
Local Run/Stop control via remote
Keyboard
2
Local Run/Stop control via keyboard
Com
3
Local Run/Stop control via communication
Modbus Instance no/DeviceNet no:
43010
Profibus slot/index
168/169
Fieldbus format
UInt
Modbus format
UInt
Stp
Standard
A
Stp
Standard
A
Default:
0
Range:
0–9999
Default:
R + L
R
1
Speed direction is limited to right rota-
tion. The input and key RunL are disa-
bled.
L
2
Speed direction is limited to left rotation.
The input and key RunR are disabled.
R+L
3
Both speed directions allowed.
Stp
0
A
Right
Left
Stp
R+L
A
Содержание F33 Series
Страница 1: ...TECO F33 Variable Speed Drive Instruction manual English Software version 4 2X...
Страница 3: ......
Страница 33: ...30 Getting Started...
Страница 51: ...48 Main Features...
Страница 53: ...50 EMC and Machine Directive...
Страница 59: ...56 Operation via the Control Panel...
Страница 65: ...62 Serial communication...
Страница 159: ...156 Troubleshooting Diagnoses and Maintenance...
Страница 165: ...162 Options...
Страница 179: ...176 Technical Data...
Страница 187: ...184 Menu List...