Functional Description
113
Communication information
Min Pre Alarm Response delay [4182]
Sets the delay time between the first occurrence of min
pre alarm condition and after when the alarm is given.
Communication information
With load type Basic, [415], used the Min Alarm Margin
sets the band under the Normal Load, [41B], menu that
does not generate an alarm. With load type Load Curve,
[415], used the Min Alarm Margin sets the band under
the Load Curve, [41C], that does not generate an
alarm. The Max Alarm Margin is a percentage of nomi-
nal motor torque.
Communication information
Min Alarm Response delay [4192]
Sets the delay time between the first occurrence of min
alarm condition and after when the alarm is given.
Communication information
Autoset Alarm [41A]
The Autoset Alarm function can measure the nominal
load that is used as reference for the alarm levels. If the
selected Load Type [415] is Basic it copies the load the
motor is running with to the menu Normal Load [41B].
The motor must run on the speed that generates the
load that needs to be recorded. If the selected Load
Type [415] is Load Curve it
performs a test-run and pop-
ulates the Load Curve [41C] with the found load values.
Communication information
Modbus Instance no/DeviceNet no: 43328
Profibus slot/index
169/232
Fieldbus format
Long, 1=1%
Modbus format
EInt
Default:
0.1 s
Range:
0-90 s
Modbus Instance no/DeviceNet no: 43332
Profibus slot/index
169/236
Fieldbus format
Long, 1=0.1 s
Modbus format
EInt
Default:
15%
Range:
0-400%
Modbus Instance no/DeviceNet no: 43329
Profibus slot/index
169/233
Fieldbus format
Long, 1=1%
Modbus format
EInt
Stp
0.1s
A
Stp
15%
A
Default:
0.1 s
Range:
0-90 s
Modbus Instance no/DeviceNet no: 43333
Profibus slot/index
169/237
Fieldbus format
Long, 1=0.1 s
Modbus format
EInt
WARNING: When autoset does a test run the
motor and application/machine will ramp up
to maximum speed.
NOTE: The motor must be running for the Autoset Alarm
function to succeed. A not running motor generates a
“Failed!” message.
Default:
No
No
0
Yes
1
Modbus Instance no/DeviceNet no: 43334
Profibus slot/index
169/238
Fieldbus format
UInt
Modbus format
UInt
Stp
0.1s
A
Stp
No
A
Содержание F33 Series
Страница 1: ...TECO F33 Variable Speed Drive Instruction manual English Software version 4 2X...
Страница 3: ......
Страница 33: ...30 Getting Started...
Страница 51: ...48 Main Features...
Страница 53: ...50 EMC and Machine Directive...
Страница 59: ...56 Operation via the Control Panel...
Страница 65: ...62 Serial communication...
Страница 159: ...156 Troubleshooting Diagnoses and Maintenance...
Страница 165: ...162 Options...
Страница 179: ...176 Technical Data...
Страница 187: ...184 Menu List...