Return To Table of Contents
20
2141-209-002 REV H
www.stryker.com
Summary of Safety Precautions
CAUTION
• Always plug the product into a wall outlet (regulated AC power source) when not in use to maintain a sufficient
battery charge and to maximize product performance while operating on battery power.
• Always immediately replace batteries that have corrosion at the terminals, display cracking, have expanded or
bulging sides, or no longer can maintain a full charge.
• Always use only Stryker authorized batteries when replacing the batteries. Use of non-Stryker batteries may lead
to unpredictable system performance.
• Upon a Battery Low alarm (Battery Low LED on Footboard and audible beep), stop using the Zoom motorized drive
and recharge the batteries immediately. Ignoring the Battery Low alarms may cause your batteries to degrade
quicker than normal and may decrease battery life.
• Always clean Velcro® after each use. Saturate Velcro with disinfectant and allow disinfectant to evaporate.
Appropriate disinfectant for nylon Velcro should be determined by the hospital.
• Do not move footboards from one product to another. Individual products may have different options. Mixing
footboards could result in unpredictable operation of the product.
• Do not use the siderails to move the product. Move the product using the integrated handles in the headboard and
footboard.
• Do not use pencils, pen caps, pen tips, or other pointed objects to tap the touch screen display. Using excessive
pressure may damage the footboard control panel and the touch screen display.
• Always use extra supervision when using a mattress or support surface thicker than six in. (15,4 cm).
• Do not allow sharp objects to come into contact with the support surface that could puncture, tear, or cut the cover.
• Make sure that you set the desired product parameters before enabling iBed® Awareness.
• Do not use accessories that cover the footboard and outside siderail LED light bars.
• Do not turn off the iBed® Awareness alarm. You will lose access to the event manager that displays the compromised
parameter condition.
• Do not hang IV bags that exceed 22 lb (10 kg) onto the IV pole.
• Always make sure that the IV pole is at a low height to pass safely through door openings.
• Do not use the IV pole as a push/pull device.
• Always make sure that the clip is stable when installed.
• Do not inset tubes that are larger than 0.75 in. into the line management clip.
• Always sterilize the clip after each use.
• Always make sure that the clip is stable when installed.
• Always unplug the product before cleaning or servicing.
• Always unplug the product, set the brakes, and place blocks under the litter frame for support when working under
the product.
• Always make sure that you wipe each product with clean water and thoroughly dry each product after cleaning.
Some cleaning products are corrosive in nature and may cause damage to the product if you use them improperly.
If you do not properly rinse and dry the product, a corrosive residue may be left on the surface of the product that
could cause premature corrosion of critical components. Failure to follow these cleaning instructions may void
your warranty.
• Do not steam clean, pressure wash, ultrasonically clean, or immerse any part of the product in water. Exposure to
water may damage the internal electric parts. These methods of cleaning are not recommended and may void this
product’s warranty.
Содержание InTouch FL27 series
Страница 2: ......
Страница 158: ...Return To Table of Contents 158 2141 209 002 REV H www stryker com Coiled Power Cord 27 2782 Rev A Reference Only ...
Страница 250: ......
Страница 251: ......