![Stratasys Objet260 Connex Скачать руководство пользователя страница 198](http://html1.mh-extra.com/html/stratasys/objet260-connex/objet260-connex_user-manual_1383595198.webp)
Objet260 User Guide
6 Operating and Maintaining the Objet260 3D Printer
DOC-37004 Rev. E
6-65
Continue with
"UV Measurement " on the next page
External UV Meter
The following steps apply when using a stand-alone UV meter. They do not
apply when using the Stratasys UV sensor box connected to the printer.
1. When the following screen appears, open the printer and place the UV
sensor box at the rear edge of the tray, in the center.
Figure 6-96 Sensor placement screen
2. Lead the cable out of the printer so that you can close the printer, and
tape it down to make sure that it does not interfere with the moving print
block.
Tape the cable to the build tray to keep it in place.
Figure 6-97 Correct UV-sensor placement
3. Close the printer, while checking that the sensor does not move out of
position.
4. Set the UV meter to measure mJ/cm2.
5. Set the range on the meter to 2,000.