![Stratasys Objet260 Connex Скачать руководство пользователя страница 215](http://html1.mh-extra.com/html/stratasys/objet260-connex/objet260-connex_user-manual_1383595215.webp)
Objet260 User Guide
6 Operating and Maintaining the Objet260 3D Printer
DOC-37004 Rev. E
6-82
Test Name
Description
Possible Reason for Failure
Head/Block Heaters
Tests the heaters in the print heads
and in the print-block body.
Faulty heaters or thermistors.
UV Lamps
Tests each UV lamp at the High
Quality power level.
Faulty UV lamp.
Faulty UV power supply.
Disconnected UV cable.
Axes Limit
Tests the hardware and software
limits of all axes.
Faulty hardware sensors.
Wrong
Max Position
parameter.
Parameter Sanity
Check
Compares the values of all printer
parameters (in cfg files) to the
required values.
One or more of the printer parameters
is not within the required range.
Details appear in the BIT report.
Vacuum
Tests the vacuum level in the print
block.
• Faulty vacuum sensor.
• Vacuum leakage.
• Wrong parameters.