Run the Head Optimization wizard whenever the condition of print heads
is negatively affecting the quality of printed models, or if you suspect that
there is a problem with one or more of the print heads.
Note:
Allow at least 40-50 minutes per mode for performing this procedure
(not including time required for replacing faulty print heads). To accurately
test and calibrate print heads, they must be clean. If necessary, run the Head
Cleaning wizard before beginning this procedure.
To test and calibrate the print heads:
1. Prepare—
❒
disposable cleaning gloves (any clean, powder-free protective gloves)
❒
pink paper
❒
the Missing Nozzles ruler
❒
the scale supplied for use in the Head Optimization wizard
Important:
Ensure that the scale is calibrated and charged before
beginning this procedure. It is highly recommended to connect the scale
to the wall power socket when running this wizard.
2. Check that there is a material cartridge loaded in the M3 slot. If necessary,
insert a cartridge that contains
different
material than is loaded in the
other slots, or insert a cleanser cartridge.
Note:
The Head Optimization wizard will not operate if the M3 cartridge
slot is empty.
3. Start the Head Optimization wizard from the
Options
menu.
Figure 6-55 Starting the Head Optimization wizard
4. In the opening wizard screen, click
Next
to begin.
The
Wizard Conditions
screen appears.
5. Read the conditions, select
I Agree
and click
Next
.