![Stratasys Objet260 Connex Скачать руководство пользователя страница 201](http://html1.mh-extra.com/html/stratasys/objet260-connex/objet260-connex_user-manual_1383595201.webp)
Objet260 User Guide
6 Operating and Maintaining the Objet260 3D Printer
DOC-37004 Rev. E
6-68
Calibrating the
Load Cells
Load cells are sensors that measure the weight of the material cartridges and
the waste container in the printer. It is important that you periodically check
that the weight measurements are accurate to prevent unnecessary waste of
printing materials. It is recommended that you calibrate the load cells once a
month.
To calibrate load cells:
1. Start the Load Cell Calibration wizard from the
Options
menu.
2. In the following screen, select one or more load cells that you want to
calibrate.
Figure 6-102 Load cell selection
3. Remove each selected cartridge from the materials cart, and click
Next
.
Figure 6-103 Confirmation of cartridge removal
4. In the next wizard screen, observe the numbers and wait until the level is
relatively stable—two units above or below the average level shown.