Commissioning an inverter
Operation manual POSIDYN® SDS 5000
ID 442289.06
WE
KEEP
THINGS
MOVING
25
3
3.2
Device state machine acc. to DSP 402
The device state machine according to DSP 402 has the same states as in the standard device state machine.
The following table shows the designation of the states according to DSP 402.
Display
a)
a) The display of the device states may be different to the form shown depending on the applications.
Designation according to DSP 402
Or
Not ready to switch on
Switch on disabled
Ready to switch on
Switched on
Operation enabled
(2nd line flashing)
Fault
Fault reaction active
Quick stop active
XDS 5000
V5.X
±0Rpm 0.0A
0: Self test
±0Rpm 0.0A
1: ONdisable
±0Rpm 0.0A
2: ReadyforON
±0Rpm 0.0A
3: Switched on
±0Rpm 0.0A
4: Enabled
Fault
No.X: type of fault
±0Rpm 0.0A
7: Quick stop