Parameterizing brake data
ID 442289.06
48
Operation manual POSIDYN® SDS 5000
7
WE
KEEP
THINGS
MOVING
7.1
B20 = 0:V/f-control
Proceed as follows for parameterization:
You can make these settings with the
General settings
assistant on the
Holding brake
page:
Fig. 7-1
: General settings
assistant,
Holding brake
page
Parameterize the brake control for
B20
=
0:V/F controller
1. Activate the brake control in parameter
F08
.
2. Specify which brakes are connected to the brake module in
F09
.
3. Enter the speed when the brake should be set in
F02
.
4. Enter the speed when the brake should be released in
F01
.
5. Enter the time that the brake requires to be set in
F07
. If you use two brakes at the brake module, enter
the one with the longer set time.
6. Enter the time that the brake requires to be released in
F06
. If you use two brakes at the brake module,
enter the one with the longer release time.
7. Transfer the parameters to the inverter and save them in it.
8. Switch the inverter off and back on again.
You have now parameterized the brake control.