Diagnosis
Operation manual POSIDYN® SDS 5000
ID 442289.06
WE
KEEP
THINGS
MOVING
143
13
13.2
Display
The display gives the user a detailed response message on the state of the inverter. In addition to the
indication of the parameters and events, the device states are shown.
The display permits an initial diagnosis without additional aids.
13.2.1
General
After the
self-test
of the inverter, the operation indication appears on the display. Depending on the
configuration and the current device state, the first and second line of the display may differ from what is
shown in the example. Im Picture shows the configuration
fast ref. value
in the device
state enabled
. See
chap. 3 for device states.
If no axis is active, this is indicated with an asterisk (*). The active axis is then shown when it differs from axis
no. 1. Only for active brake chopper or active local mode does the appropriate symbol appear on the
display.
Fig. 13-2: Display indication
ERROR (red)
RUN (green)
ON
OFF
Fault.
ERROR (red)
RUN (green)
Flashing at 8 Hz
OFF
No configuration active.
LEDs
State of the inverter
REMOTE
(blue)
OFF
No remote maintenance active.
REMOTE
(blue)
Repeatedly
lights up very
quickly
Connection to the teleserver is being
established.
REMOTE
(blue)
Steady flashing Inverter is waiting for the connection
to POSITool.
REMOTE
(blue)
Continuously lit Connection is completely set up and
remote maintenance can be
performed.
LEDs
State of the inverter
3000 rpm 1.3A
4: Enabled
Brake chopper
active
Device state
Axis no. 2 active
Current
Speed